Results 51 to 60 of about 25,055 (235)

Effect of Two Therapeutic Renal Diets on Hormonal and Regulatory Pathways Affecting Calcium Homeostasis in Cats With Early‐Stage Chronic Kidney Disease

open access: yesJournal of Animal Physiology and Animal Nutrition, EarlyView.
ABSTRACT Chronic kidney disease (CKD) is a known risk factor for hypercalcemia in cats. Phosphate‐restricted diets have also been implicated in causing hypercalcemia, in part because phosphate restriction increases the Ca:P ratio. The primary objective of this study was to evaluate the impact of two different therapeutic renal foods on ionized (iCa ...
Jean A. Hall   +4 more
wiley   +1 more source

THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE [PDF]

open access: yesChemistry Journal of Moldova: General, Industrial and Ecological Chemistry, 2010
A potentiometric selective sensor based on trinuclear chromium(III) complex as a novel ionophore for the thiocyanateselective electrode is reported. The sensor displays a near Nernstian slope of 57 ± 2 mV per decade, over a wide pH range 3 - 11.
Mihail Revenco   +2 more
doaj  

Characterisation of reduction state of cystine linkages on wool fibre surface under heterogeneous reaction conditions

open access: yesPolymer Testing, 2022
As a natural biomaterial with outstanding properties, keratin fibres hold promising potential in many application fields. The reduction of disulphides in keratin to the corresponding thiols plays a central role e.g.
Madita Buchacher   +2 more
doaj   +1 more source

A Novel Green Method for Producing Medical‐Grade Chitosan From Loligo plei Squid Pens

open access: yesJournal of Applied Polymer Science, Volume 143, Issue 25, July 5, 2026.
This work demonstrates a sustainable and simplified process for the production of medical‐grade chitosan from the feathers of the squid Loligo plei, employing mild chemical treatments to preserve the integrity of the polymer while achieving high purity and performance.
Talita Martins   +7 more
wiley   +1 more source

Modelling and optimization of surfactant sensor response characteristics for the use in surface water and wastewater analysis

open access: yesZaštita Materijala, 2014
The theoretical model of potentiometric titration curves of sodium dodecyl sulfate (anionic surfactant) was proposed and the response parameters of two surfactant sensors (commercial and self-made) were investigated.
Stanisavljev Ana Komanović   +2 more
doaj   +1 more source

Characterization of Shewanella oneidensis MtrC: a cell-surface decaheme cytochrome involved in respiratory electron transport to extracellular electron acceptors [PDF]

open access: yes, 2007
MtrC is a decaheme c-type cytochrome associated with the outer cell membrane of Fe(III)-respiring species of the Shewanella genus. It is proposed to play a role in anaerobic respiration by mediating electron transfer to extracellular mineral oxides that ...
AI Tsapin   +52 more
core   +1 more source

Anion Mobility Renormalization Reveals Backbone‐Dependent Tortuosity in Anion Exchange Membranes

open access: yesChemElectroChem, Volume 13, Issue 11, 3 June 2026.
Backbone polarity governs nanophase separation and tortuosity in anion exchange membranes (AEMs). The anion mobility across PPO‐ and PSU‐based ionomer membranes with quaternary ammonium groups depends exponentially on concentration. Extracted porosity–tortuosity ratios reveal lower tortuosity in PPO due to stronger PSU hydrophilicity.
Philippe Knauth, Maria Luisa Di Vona
wiley   +1 more source

Potentiometric characterisation of cyclodextrin inclusion complexes of local anaesthetics [PDF]

open access: yes, 2011
The complexation of several local anaesthetics by β and γ-cyclodextrins was studied by potentiometry with glass electrode. Tetracaine and dibucaine complexation constants were determined at 25°C in the presence of 0.1 M of NaCl.
Brandariz, Isabel, Iglesias, Emilia
core   +4 more sources

The titrating conditions in the potentiometric titration of zinc

open access: yesBUNSEKI KAGAKU, 1964
硫酸酸性におけるフェロシアン化カリウムによる亜鉛の定量を,さまざまな滴定条件のもとに,白金-タングステン双金属電極を用いて電位差滴定を行ない,滴定に及ぼす諸影響を検討した.20℃では硫酸濃度,硫酸アンモニウム濃度によって終点の滴定量が異なるが,滴定溶液の容積100mlあたり硫酸濃度範囲0~0.05N,硫酸アンモニウム20gで一定の滴定速度のもとに行なうと,終点までの滴定量の再現性および電位差滴定曲線がともに良好で,終点における電位差変化が大きい.亜鉛濃度0.0025~0.0125Mの溶液を,滴定誤差約+1.5%で定量することができる.60℃ではすみやかに終点に達し,硫酸濃度,硫酸アンモニウム濃度,滴定時間の影響はより小さくなるが,終点における電位差変化が小さい.滴定誤差は約-1.2%である.
Saburo MIYAZAWA, Fumihiko OTSUKA
openaire   +2 more sources

Assessing on‐farm variability of climate‐smart soybean varieties under full packages versus farmers’ practices in Western Oromia, Ethiopia

open access: yesAgrosystems, Geosciences &Environment, Volume 9, Issue 2, June 2026.
Abstract Farmers' soybean [Glycine max L. (Merrill)] yields and performance were highly variable under their usual practices (without full recommended packages), indicating that current soybean production constraints likely prevent consistent results in western Oromia, Ethiopia.
Alemayehu Dabesa   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy