Results 91 to 100 of about 8,691,345 (183)
Over the past few years, transmission grid in the USA has seen numerous unintentional tripping events of large-scale inverter based resources (IBRs). These trippings were primarily caused by non-standard settings and certain fault ride through controls ...
Shah Mohazzem Hossain +2 more
doaj +1 more source
To enhance frequency support and fault ride-through capabilities of MMC-HVDC system, an MMC multi-time scale coordinated control strategy considering the regulation dead zone is proposed, which achieves wide-area coordinated complementarity of multiple ...
Shouqi Jiang +5 more
doaj +1 more source
Peducing the frequency of switching overvoltage in generator networks
THE PURPOSE of the study is to study the problem of switching overvoltages in 10 kV generator networks. Using the Matlab Simulink package, create a model of common auxiliaries of a 10/0.4 kV power station, calculate the overvoltage at different sections ...
R. A. Belsky +3 more
doaj +1 more source
Hybrid and solid-state breakers offer new possibilities in the power grid by enabling faster switching, and by simplifying dc breaking. However, they consists of expensive power electronic components that are sensitive to overvoltage transients and ...
Saers, R. +3 more
core +1 more source
Aiming at the accidents of high-voltage electrical equipment in electric locomotive such as burn out of resistance-capacity absorption device, explosion damage of arrester, DC over-voltage of converter led by overhead line resonant overvoltage happening ...
Limin FENG
doaj
Research on motor overvoltage issues in metallurgical environments using three-level inverters
Industries such as nuclear power plants and underground mining are characterized by space constraints,forcing the use of long-wire cables to power motors.The impedance mismatch between long-wire cables and motors leads to overvoltage phenomena at motor ...
L. L. Meng, W. Dai
doaj
Preventing overvoltage in a distribution grid with large penetration of photovoltaic power
Photovoltaic (PV) power generation is an important component in the future energy system. High penetration of PV power in a distribution power grid might however lead to overvoltage, i.e. +10% of rated voltage, for end-users. This study compares PV power
Widén, Joakim, +3 more
core
During the operation of group trains, the trains frequently pass through the neutral zone. Then, the generated closing overvoltage will cause serious insulation damage to the traction power supply system and the trains′ high-voltage equipment box.
WANG Zhoulong +5 more
core +1 more source
Study on the Influence of Grounding Resistance on Cable Fault Overvoltage
The cable grounding connecting method and grounding resistance have a significant influence on the cable fault overvoltage. This paper considers a 500 kV long cable project in Beijing as the research object; a model was implemented in ATP-EMTP, and ...
Changyuan Xiang +4 more
core +1 more source
Line commutated converter based high voltage direct current (LCC-HVDC) is the key to large-scale grid connection and long-distance transmission of renewable energy. However, faults such as DC blocking and commutation failure may lead to short-term excess
HUA Zhuhu +5 more
core +1 more source