Results 71 to 80 of about 3,794 (179)
Lightning Overvoltage Response Modeling and Protection Design for Solid State Transformer
The rapid development of the AI and ICT industry has driven massive data center construction. Compared to conventional LFT (line-frequency transformer)-isolated conversion system, SST-based uninterruptible power supply solution offers high efficiency ...
Jiatong Zhang +4 more
doaj +1 more source
Abstract Continuous, high‐frequency monitoring is essential to capture rapid phenological transitions and dynamic crop responses to the environment. However, most phenotyping platforms lack the temporal resolution and automation required for consistent, season‐long trait assessment.
Worasit Sangjan +5 more
wiley +1 more source
Inverted unified power quality conditioner to compensate overvoltage [PDF]
Introducción: Los acondicionadores unificados de calidad de la potencia UPQC permiten corregir, en los sistemas eléctricos, distorsiones de la forma de onda en estado estable, como los armónicos o el parpadeo, así como el factor de potencia.Objetivo ...
Garcés Gómez, Yeison Alberto +6 more
core +1 more source
As voltage measuring devices are widely used in the high voltage power system with a primary‐secondary‐fusion structure, electronic voltage transformers are directly connected to the primary conductor and would face much more serious electromagnetic ...
Houda Zhu +5 more
doaj +1 more source
The coral‐reef‐like nanoporous architecture of Ni, designed through NiCu dealloying, promotes HER and OER by increasing active site density, facilitating charge transfer kinetics, and expanding the electrochemically active surface area, resulting in improved alkaline water electrolysis efficiency.
Mohmmad Khalid +2 more
wiley +1 more source
© 2018 IEEE. Overvoltage is one of the major issues on distribution grids with high penetration of photovoltaic (PV) generation. Overvoltage could be prevented through the control of active/reactive power of PVs.
Dahal, Sudarshan +9 more
core +1 more source
This study probes why polymer electrolyte membrane electrolyzers lose efficiency under different operating profiles. Using electrical tests, microscopy, and spectroscopy, Ti‐PTL passivation is established as the dominant cause for increased Ohmic resistance in samples aged under constant and triangular current profiles for 88 h.
Annik Bernhardt +13 more
wiley +1 more source
During the operation of group trains, the trains frequently pass through the neutral zone. Then, the generated closing overvoltage will cause serious insulation damage to the traction power supply system and the trains′ high-voltage equipment box.
WANG Zhoulong +5 more
core +1 more source
Generator step up transformer overvoltage protection in EPS power plants
This paper presents the current state of the overvoltage protection of generator transformers in power plants of the Power Company of Serbia (EPS) and gives a critical overview of their overvoltage protection.
Mrvić Jovan +2 more
core +1 more source
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme +7 more
core +1 more source