Results 51 to 60 of about 8,691,345 (183)

Generator step up transformer overvoltage protection in EPS power plants [PDF]

open access: yes, 2015
This paper presents the current state of the overvoltage protection of generator transformers in power plants of the Power Company of Serbia (EPS) and gives a critical overview of their overvoltage protection.
Mrvić Jovan   +2 more
core   +1 more source

The Impact of Various Contact Structures on the Microscopic Surface Condition of Vacuum Interrupters During Capacitive Switching

open access: yesHigh Voltage, EarlyView.
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng   +6 more
wiley   +1 more source

Load Rejection Overvoltage Suppression and Parameter Design Method of UHV AC Transmission Line

open access: yes
UHV (ultra-high voltage) by instant AC transmission system is accompanied by huge reactive power transmission. When the load drops sharply, it is easy to produce serious power frequency overvoltage, which is also defined as load rejection overvoltage ...
Wang Ma   +6 more
core   +1 more source

Electromagnetic processes and conditions of occurring resonance overvoltage in power transformer windings

open access: yesИзвестия Томского политехнического университета: Инжиниринг георесурсов, 2019
The relevance of the study: At the present stage of CIS countries network development the problem of increase the operation reliability of transformers, which main part has been already out of date is of the first-priority. The problem is also up to date
Myroslav Sabat   +3 more
doaj   +2 more sources

Zero‐Current Switching Based Model Predictive Control of a Double‐Extended Overlapped Alternate Arm Converter Used in the VSC–HVDC System

open access: yesHigh Voltage, EarlyView.
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley   +1 more source

Comprehensive Design and Experimental Validation of 30 kV Ultra‐Fast Flexible Controllable Arresters for HVDC Systems

open access: yesHigh Voltage, EarlyView.
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang   +4 more
wiley   +1 more source

Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device

open access: yesHigh Voltage, EarlyView.
ABSTRACT Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc ...
Yeqiang Deng   +4 more
wiley   +1 more source

The Lightning Protection Assessment of Distribution Lines with Considering Frequency Grounding System [PDF]

open access: yesIranian Journal of Electrical and Electronic Engineering
Ensuring the protection of all components within power systems from lightning-induced overvoltage is crucial. The issue of power interruptions caused by both direct and indirect lightning strikes (LS) presents significant challenges in the electrical ...
Aida Gholami   +2 more
doaj  

Research on influencing factors of arc grounding over-voltage in mine power supply system

open access: yesGong-kuang zidonghua, 2017
In order to comprehensively study influence factors such as grounding resistance, line resistance, fault location, grounding capacitance, interphase capacitance and arc ignition time on arc grounding over-voltage in mine power supply system, typical mine
LIU Jucai   +6 more
doaj   +1 more source

Study on Arc Discharge Law and Ablation Characteristics of GIS Basin Insulator Sample Surface Under High Voltage and Large Current

open access: yesHigh Voltage, EarlyView.
ABSTRACT Gas‐insulated metal‐enclosed switchgear (GIS) has emerged as the preferred choice for power grid engineering due to its outstanding performance. However, issues related to arc discharge and thermal damage to basin insulators caused by metal contaminants have become increasingly significant.
Bingbing Dong   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy