Results 61 to 70 of about 8,691,345 (183)

Design of Zero Overvoltage Switching tailored power electronics

open access: yes
25102517Zero Overvoltage Switching (ZOS) can be used for clean switching transitions without overvoltage oscillations and unlimited switching speed, leading to the elimination of switching losses.
März, Martin   +2 more
core   +1 more source

Co‐Optimisation of Battery Energy Storage Systems for Voltage Regulation and Reverse Power Flow Control in PV‐Enriched Low Voltage Distribution Network

open access: yesIET Smart Energy Systems, EarlyView.
A hybrid GA–PSO framework determines the optimal placement and sizing of distributed battery energy storage systems in a PV‐enriched low voltage feeder, whereas dynamic consensus control (DCC) coordinates their operation. The integrated approach mitigates voltage rise and reverse power flow and promotes balanced utilisation of multiple storage units ...
Nirakar Nepal   +4 more
wiley   +1 more source

Overvoltage Elimination via Distributed Backstepping-Controlled Converters in Near-Zero-Energy Buildings Under Excess Solar Power to Improve Distribution Network Reliability

open access: yesEnergies
This work uses battery-coupled power electronic converter systems and distributed backstepping controllers to improve the reliability of electrical distribution networks.
J. Dionísio Barros   +3 more
doaj   +1 more source

Overvoltage Characteristics of ±800 kV MMC‐HVDC Overhead‐Cable Hybrid Lines for Large‐Scale Hydropower Delivery Under Monopolar Grounding Faults

open access: yesVector: The Journal of Engineering, Volume 2027, Issue 1, January/December 2027.
For ±800 kV MMC‐HVDC overhead‐cable hybrid lines, monopolar grounding faults drive the maximum healthy‐pole overvoltage to 2.004 p.u., notably above the 1.824 p.u. of a full‐overhead line. Cable‐internal faults further produce a damped, quasi‐periodic zero‐crossing oscillation whose period scales with the fault‐to‐junction distance, offering a novel ...
Xiangyu Yang   +4 more
wiley   +1 more source

Study on power frequency overvoltage and wind turbine disconnection probability during non-full-phase operation

open access: yesJournal of Physics: Conference Series
Abstract Experimental results indicate that during non-full-phase operation following a single-phase transient grounding fault, power frequency overvoltage occurs in the system. In systems with significant wind power integration, such overvoltage may lead to the disconnection of wind turbines, thereby increasing the probability of ...
Donghui Wang, Zengping Wang, Tong Wang
openaire   +1 more source

Mitigation of machine neutral point overvoltage in SiC motor drives by controlling antiresonance frequency and switching frequency

open access: yes
No descrinverter-fed motors are vulnerable to premature insulation failure due to overvoltage stress across stator windings because of antiresonance phenomenon which is characterized by two oscillatory overvoltage responses that manifest at the motor ...
Xibo Yuan (11766488)   +2 more
core   +2 more sources

Lightning Overvoltage Response Modeling and Protection Design for Solid State Transformer

open access: yesIEEE Access
The rapid development of the AI and ICT industry has driven massive data center construction. Compared to conventional LFT (line-frequency transformer)-isolated conversion system, SST-based uninterruptible power supply solution offers high efficiency ...
Jiatong Zhang   +4 more
doaj   +1 more source

Continuous Entropy Change Estimation in Lithium‐Ion Batteries by Temperature‐Induced Open‐Circuit Voltage Changes

open access: yesBatteries &Supercaps, Volume 9, Issue 12, December 2026.
This article presents a fast method to estimate the entropic heat coefficient of battery cells using temperature‐induced changes in open‐circuit voltage measured by different estimation procedures, thereby simplifying the calculation of the reversible heat term.
Dominik Droese   +2 more
wiley   +1 more source

Analysis and suppression of operational overvoltage and inrush current for high‐speed trains by automatic phase‐switching technique

open access: yesHigh Voltage
When a high‐speed train approaches the insulated phase‐splitting section embedded between neighbouring power supply arms, the vacuum circuit breaker (VCB) installed on trains must be disconnected to maintain the traction power supply system as a no‐load ...
Ye Cao   +13 more
doaj   +1 more source

Current-fed Step-up DC/DC Converter for Fuel Cell Applications with Active Overvoltage Clamping

open access: yesElectrical, Control and Communication Engineering, 2010
In order to use hydrogen fuel cells in domestic applications either as main power supply or backup source, their low DC output voltage has to be matched to the level and frequency of the utility grid AC voltage.
Aleksandrs Andreiciks   +2 more
doaj   +1 more source