Results 81 to 90 of about 8,691,345 (183)

Comparative Study of Active Power Curtailment Methods of PVs for Preventing Overvoltage on Distribution Feeders

open access: yes, 2018
© 2018 IEEE. Overvoltage is one of the major issues on distribution grids with high penetration of photovoltaic (PV) generation. Overvoltage could be prevented through the control of active/reactive power of PVs.
Dahal, Sudarshan   +9 more
core   +1 more source

MULTIVULATED FREQUENCY-REGULATED ELECTRIC DRIVE OF CORD WRAPPING LINE [PDF]

open access: yes, 2018
The urgency of the work is due to the need to develop a multi-motor frequency-controlled electric drive for cord clipping lines. The study of the construction of energy-efficient multi-motor drives, with the help of reversible frequency converters, which
E. N. Gavrilov   +2 more
core   +1 more source

Suppression of Generator-Side Transient Overvoltage in a DC 600 V Power Car System Based on AZSVPWM

open access: yesEnergies
Generator-side transient overvoltage may occur in DC 600 V AC–DC–AC railway power supply systems because switching-induced common-mode voltage generated by the front-end rectifier can propagate in reverse through cable distributed parameters, grounding ...
Fangdong Hou   +4 more
doaj   +1 more source

Design of Hybrid Control Algorithm for Fault Ride-Through of Photovoltaic System

open access: yesIEEE Access, 2019
This paper proposes a novel control algorithm to enhance the fault ride-through (FRT) capability of a photovoltaic (PV) system. In this method, the overcurrent of the grid-tied inverter is suppressed to a preset value using model current predictive ...
Feng Zheng   +5 more
doaj   +1 more source

New approach to overvoltage protection of power distribution networks

open access: yes, 2008
U ovoj su radnji izvršene analize novih pristupa u prenaponskoj zaštiti srednjenaponskih elektroenergetskih mreža. Analizirani su nastanci i djelovanja prenapona, te je dan pregled postojećih metoda prenaponske zaštite u srednjenaponskim distribucijskim ...
Bago, Drago
core  

Optimum reactive power compensation methodology to minimize system overvoltage conditions

open access: yes, 2017
Sri Lankan Power system has experienced power frequency over voltages at steady state conditions predominantly at New Anuradhapura, New Chilaw and Chunnakam Grid Sub Stations. New Anuradhapura being connected to the lengthiest 220kV transmission lines
Perera, CKS
core   +1 more source

Frequency Scanning-Based Simplified Overvoltage Prediction Method for SiC Inverter-Fed Motor Drives in Electric Vehicles

open access: yesWorld Electric Vehicle Journal
Wide-bandgap power devices, particularly silicon carbide (SiC) MOSFETs, have seen widespread adoption in electric vehicle (EV) motor drive systems due to their superior switching characteristics, including high switching speeds and high switching ...
Yipu Xu   +4 more
doaj   +1 more source

Control Strategy for Asymmetric Faults on the Low-Frequency Side of a Sparse Modular Multilevel Converter

open access: yes
Sparse modular multilevel converters (SMMCs) are a new type of lightweight high-voltage large-power AC/AC converter that significantly reduces the number of components compared to modular multilevel matrix converters (M3Cs).
Yuwei Sun   +7 more
core   +1 more source

Overvoltage Suppression Filter Development for GaN Inverter-Fed Electrical Drive with Long Cable Based on Impedance Measurement

open access: yes
Wide-bandgap transistors have short voltage rise and fall times, thus leading to overvoltage at the end of the cable connecting the inverter and the motor.
Kaspars Kroičs, Jānis Voitkāns
core   +1 more source

Mechanism Analysis and Simulation Study of Closing Overvoltage Fault in EMU Circuit Breaker

open access: yesChengshi guidao jiaotong yanjiu
Objective The overvoltage caused by circuit breaker closing will aggravate the insulation aging of high voltage equipment when EMU (electric multiple units)passes neutral section.
ZHANG Mingrui   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy