Results 41 to 50 of about 82,174 (302)
This perspective highlights emerging insights into how the circadian transcription factor CLOCK:BMAL1 regulates chromatin architecture, cooperates with other transcription factors, and coordinates enhancer dynamics. We propose an updated framework for how circadian transcription factors operate within dynamic and multifactorial chromatin landscapes ...
Xinyu Y. Nie, Jerome S. Menet
wiley +1 more source
Reliable and dedicated protection of the transformer is the main requirement in the power system due to the supervision of a highly expensive equipment transformer. Non‐linear characteristics of the transformer give mysterious behaviour for the period of
Maulik Raichura +2 more
doaj +1 more source
Analisis Kinerja Sistem Proteksi Berdasarkan Frekuensi Gangguan di Gardu Induk 150 KV Garuda Sakti [PDF]
With the disruption that can not be predicted, we need a safety equipment (protection system) are precise and reliable. The purpose of this study was to determine the quantity of interference, protection system performance, reliability and power ...
\u27, A. (Ardianto) +2 more
core
Design and implementation of 30kW 200/900V LCL modular multilevel based DC/DC converter for high power applications [PDF]
This paper presents the design, development and testing of a 30kW, 200V/900V modular multilevel converter (MMC) based DC/DC converter prototype. An internal LCL circuit is used to provide voltage stepping and fault tolerance property.
Aboushady, A. +3 more
core +2 more sources
The newfound relationship between extrachromosomal DNAs and excised signal circles
Extrachromosomal DNAs (ecDNAs) contribute to the progression of many human cancers. In addition, circular DNA by‐products of V(D)J recombination, excised signal circles (ESCs), have roles in cancer progression but have largely been overlooked. In this Review, we explore the roles of ecDNAs and ESCs in cancer development, and highlight why these ...
Dylan Casey, Zeqian Gao, Joan Boyes
wiley +1 more source
Discussion of Auxiliary Power Source Open-Phase Protection in Nuclear Power Plant
[Objective] The auxiliary power source in nuclear power plant operates at no-load normally, the protection cannot alarm when it occurs single phase open, but this open-phase condition will threaten the nuclear safety seriously, it should assemble special
Shunhua WU +7 more
doaj +1 more source
Differential Protection of a Three-Phase Power Transformer Using Hall Effect Current Transducer [PDF]
In a power system, transformers and other electrical equipment need to be protected not only from short circuit, but also from abnormal operating conditions, such as over loading, and differential fault protection.
Fathollahi Fard, Ali Asghar
core
Protection of power transformer using microcontroller-based relay [PDF]
This paper describes the design and implementation of the micro controller-based system for protecting power transformer. The system includes facilities for discrimination between internal fault current and magnetizing inrush current, differential ...
Bashi, Senan Mahmood +4 more
core +1 more source
Differential Protection of Power Transformer using Wavelet Transform
This paper presents wavelet transform method for the analysis of differential currents of power transformer which can act as an accurate classifier between magnetizing inrush current and internal faults to avoid the needless tripping of circuit breaker.
Mudita Banerjee*, Dr. Anita Khosla
openaire +1 more source
Structural biology of ferritin nanocages
Ferritin is a conserved iron‐storage protein that sequesters iron as a ferric mineral core within a nanocage, protecting cells from oxidative damage and maintaining iron homeostasis. This review discusses ferritin biology, structure, and function, and highlights recent cryo‐EM studies revealing mechanisms of ferritinophagy, cellular iron uptake, and ...
Eloise Mastrangelo, Flavio Di Pisa
wiley +1 more source

