Results 161 to 170 of about 36,624 (315)

Gender-Specific Outcomes in TAVI with Self-Expandable Valves: Insights from a Large Real-World Registry. [PDF]

open access: yesJ Clin Med
Sticchi A   +20 more
europepmc   +1 more source

Automated rapidplan model validation using Eclipse scripting API

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma   +2 more
wiley   +1 more source

Comparative safety and efficacy of new-generation single-layer polytetrafluorethylene- versus polyurethane-covered stents in patients with coronary artery perforation for the RECOVER (REsults after percutaneous interventions with COVERed stents) Investigators. [PDF]

open access: yesCardiovasc Interv Ther
Voll F   +26 more
europepmc   +1 more source

Long‐term stability analysis of beam shape in a robotic radiosurgery system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aimed to investigate the long‐term stability of CyberKnife beam profile parameters and assess their compliance with existing quality assurance (QA) guidelines. We evaluated beam profiles in both standard and diagonal planes over 3.5 years post‐installation to detect potential issues and ensure consistent beam quality.
Ryoichi Hinoto   +4 more
wiley   +1 more source

Beam model development and clinical experience with RadCalc for treatment plan quality assurance in online adaptive workflow with an MR‐linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen   +3 more
wiley   +1 more source

Robot-Assisted Cardiovascular Interventions. [PDF]

open access: yesJ Soc Cardiovasc Angiogr Interv
George JC, Varghese V, Madder RD.
europepmc   +1 more source

Dosimetric evaluation and clinical application of collimated apertures with proton beam line scanning in stereotactic radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Stereotactic radiotherapy (SRT) is a highly effective treatment with precision for small, localized lesions. Proton therapy, characterized by the Bragg peak, offers superior dose conformity compared to photon‐based approaches. However, challenges remain in minimizing lateral penumbra and optimizing dose delivery, particularly for small
Chen‐Yu Chou   +3 more
wiley   +1 more source

Letter from the Editor in Chief. [PDF]

open access: yesJ Innov Card Rhythm Manag
Nair D.
europepmc   +1 more source

Home - About - Disclaimer - Privacy