Results 61 to 70 of about 926,093 (348)

Optimal Calculation of Mean Pressure From Pulse Pressure

open access: yesAmerican Journal of Hypertension, 2023
Abstract BACKGROUND There are six different formulae for estimating mean arterial pressure (MAP) from systolic and diastolic pressure readings. This study is to determine the optimum formula for calculating MAP when compared to the gold standard approach, which is the area under the curve of an ...
Liam Y H Tien   +3 more
openaire   +2 more sources

Prediction of Myasthenia Gravis Worsening: A Machine Learning Algorithm Using Wearables and Patient‐Reported Measures

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background Myasthenia gravis (MG) is a rare disorder characterized by fluctuating muscle weakness with potential life‐threatening crises. Timely interventions may be delayed by limited access to care and fragmented documentation. Our objective was to develop predictive algorithms for MG deterioration using multimodal telemedicine data ...
Maike Stein   +7 more
wiley   +1 more source

2.2 TRANSFER FUNCTION-DERIVED CENTRAL PRESSURE AND CARDIOVASCULAR EVENTS: THE FRAMINGHAM HEART STUDY

open access: yesArtery Research, 2013
Relations between central versus brachial blood pressure and major cardiovascular disease (CVD) events remain controversial. Central measures derived using radial tonometry and a generalized transfer function as implemented using the SphygmoCor device ...
G.F. Mitchell   +7 more
doaj   +1 more source

Tailored laser pulse chirp to maintain optimum radiation pressure acceleration of ions

open access: yes, 2018
Ion beams generated with ultra-intense lasers-plasma accelerators hold promises to provide compact and affordable beams of relativistic ions. One of the most efficient acceleration setups was demonstrated to be direct acceleration by the laser's ...
Bulanov, S. S., Mackenroth, F.
core   +1 more source

The optimization of the multi-atmospheric Ar-Xe laser [PDF]

open access: yes, 1998
The quasi-steady-state conditions of the multi-atmospheric e-beam sustained Ar-Xe laser are investigated. It is observed that the duration of the stationary period depends on the e-beam current, discharge power deposition, and gas pressure.
Gielkens, S.W.A.   +3 more
core   +2 more sources

Reduced Muscular Carnosine in Proximal Myotonic Myopathy—A Pilot 1H‐MRS Study

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Myotonic dystrophy type 2 (proximal myotonic myopathy, PROMM) is a progressive multisystem disorder with muscular symptoms (proximal weakness, pain, myotonia) and systemic manifestations such as diabetes mellitus, cataracts, and cardiac arrhythmias.
Alexander Gussew   +11 more
wiley   +1 more source

Method and apparatus for continuously monitoring blood oxygenation, blood pressure, pulse rate and the pressure pulse curve utilizing an ear oximeter as transducer Patent [PDF]

open access: yes, 1968
Ear oximeter for monitoring blood oxygenation and pressure, pulse rate, and pressure pulse curve, using dc and ac ...
Smith, J. R., Jr.
core   +1 more source

Functional Connectivity Linked to Cognitive Recovery After Minor Stroke

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Patients with minor stroke exhibit slowed processing speed and generalized alterations in functional connectivity involving frontoparietal cortex (FPC). The pattern of connectivity evolves over time. In this study, we examine the relationship of functional connectivity patterns to cognitive performance, to determine ...
Vrishab Commuri   +7 more
wiley   +1 more source

P3.19 AORTIC PULSE PRESSURE BETTER PREDICTS INCREASES ARTERIAL STIFFNESS COMPARED TO BRACHIAL AND AMBULATORY MEASUREMENTS

open access: yesArtery Research, 2013
Objectives: Hypertension is associated with increased arterial stiffness, which is an independent predictor of cardiovascular risk. Aortic systolic blood pressure (SBP) and/or pulse pressure (PP) better predicts cardiovascular events than peripheral ...
D. Terentes-Printzios   +8 more
doaj   +1 more source

Remote Estimation of Blood Pressure Using Millimeter-Wave Frequency-Modulated Continuous-Wave Radar

open access: yesSensors, 2023
This paper proposes to remotely estimate a human subject’s blood pressure using a millimeter-wave radar system. High blood pressure is a critical health threat that can lead to diseases including heart attacks, strokes, kidney disease, and vision loss ...
Lovedeep Singh   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy