Results 61 to 70 of about 926,093 (348)
Optimal Calculation of Mean Pressure From Pulse Pressure
Abstract BACKGROUND There are six different formulae for estimating mean arterial pressure (MAP) from systolic and diastolic pressure readings. This study is to determine the optimum formula for calculating MAP when compared to the gold standard approach, which is the area under the curve of an ...
Liam Y H Tien +3 more
openaire +2 more sources
ABSTRACT Background Myasthenia gravis (MG) is a rare disorder characterized by fluctuating muscle weakness with potential life‐threatening crises. Timely interventions may be delayed by limited access to care and fragmented documentation. Our objective was to develop predictive algorithms for MG deterioration using multimodal telemedicine data ...
Maike Stein +7 more
wiley +1 more source
2.2 TRANSFER FUNCTION-DERIVED CENTRAL PRESSURE AND CARDIOVASCULAR EVENTS: THE FRAMINGHAM HEART STUDY
Relations between central versus brachial blood pressure and major cardiovascular disease (CVD) events remain controversial. Central measures derived using radial tonometry and a generalized transfer function as implemented using the SphygmoCor device ...
G.F. Mitchell +7 more
doaj +1 more source
Tailored laser pulse chirp to maintain optimum radiation pressure acceleration of ions
Ion beams generated with ultra-intense lasers-plasma accelerators hold promises to provide compact and affordable beams of relativistic ions. One of the most efficient acceleration setups was demonstrated to be direct acceleration by the laser's ...
Bulanov, S. S., Mackenroth, F.
core +1 more source
The optimization of the multi-atmospheric Ar-Xe laser [PDF]
The quasi-steady-state conditions of the multi-atmospheric e-beam sustained Ar-Xe laser are investigated. It is observed that the duration of the stationary period depends on the e-beam current, discharge power deposition, and gas pressure.
Gielkens, S.W.A. +3 more
core +2 more sources
Reduced Muscular Carnosine in Proximal Myotonic Myopathy—A Pilot 1H‐MRS Study
ABSTRACT Objective Myotonic dystrophy type 2 (proximal myotonic myopathy, PROMM) is a progressive multisystem disorder with muscular symptoms (proximal weakness, pain, myotonia) and systemic manifestations such as diabetes mellitus, cataracts, and cardiac arrhythmias.
Alexander Gussew +11 more
wiley +1 more source
Method and apparatus for continuously monitoring blood oxygenation, blood pressure, pulse rate and the pressure pulse curve utilizing an ear oximeter as transducer Patent [PDF]
Ear oximeter for monitoring blood oxygenation and pressure, pulse rate, and pressure pulse curve, using dc and ac ...
Smith, J. R., Jr.
core +1 more source
Functional Connectivity Linked to Cognitive Recovery After Minor Stroke
ABSTRACT Objective Patients with minor stroke exhibit slowed processing speed and generalized alterations in functional connectivity involving frontoparietal cortex (FPC). The pattern of connectivity evolves over time. In this study, we examine the relationship of functional connectivity patterns to cognitive performance, to determine ...
Vrishab Commuri +7 more
wiley +1 more source
Objectives: Hypertension is associated with increased arterial stiffness, which is an independent predictor of cardiovascular risk. Aortic systolic blood pressure (SBP) and/or pulse pressure (PP) better predicts cardiovascular events than peripheral ...
D. Terentes-Printzios +8 more
doaj +1 more source
Remote Estimation of Blood Pressure Using Millimeter-Wave Frequency-Modulated Continuous-Wave Radar
This paper proposes to remotely estimate a human subject’s blood pressure using a millimeter-wave radar system. High blood pressure is a critical health threat that can lead to diseases including heart attacks, strokes, kidney disease, and vision loss ...
Lovedeep Singh +4 more
doaj +1 more source

