Results 71 to 80 of about 668,121 (290)
PBTTT‐OR‐R, a C14‐alkoxy/alkyl‐PBTTT polymer derivative, is of substantial interest for optoelectronics due to its specific fullerene intercalation behavior and enhanced charge‐transfer absorption. Comparing this polymer with (S) and without (O) homocoupling defects reveals that PBTTT‐OR‐R(O) forms stable co‐crystals with PC61BM, while PBTTT‐OR‐R(S ...
Zhen Liu +14 more
wiley +1 more source
The Influence of Temperature on Frequency Modulation Spectroscopy in Atom Gravimeter
Atom gravimeters use locked lasers to manipulate atoms to achieve high-precision gravity measurements. Frequency modulation spectroscopy (FMS) is an accurate method of optical heterodyne spectroscopy, capable of the sensitive and rapid frequency locking ...
Kanxing Weng +6 more
doaj +1 more source
Generalized quantum measurement
We overcome one of Bell's objections to `quantum measurement' by generalizing the definition to include systems outside the laboratory. According to this definition a {\sl generalized quantum measurement} takes place when the value of a classical ...
Bell +13 more
core +2 more sources
In this study, the interplay of dipolar dynamics and ionic charge transport in MOF compounds is investigated. Synthesizing the novel structure CFA‐25 with integrated freely rotating dipolar groups, local and macroscopic effects, including interactions with Cs cations are explored.
Ralph Freund +6 more
wiley +1 more source
Atomic Magnetometer Achieves Visual Salience Analysis in Drosophila
An atomic magnetometer (AM) was used to non-invasively detect the tiny magnetic field generated by the brain of a single Drosophila. Combined with a visual stimulus system, the AM was used to study the relationship between visual salience and oscillatory
Fan Liu +7 more
doaj +1 more source
In the classical world one can construct two identical systems which have identical behavior and give identical measurement results. We show this to be impossible in the quantum domain.
A Aspect +18 more
core +1 more source
A lack of standard approaches for testing and reporting the performance of metal halide perovskites and organic semiconductor radiation detectors has resulted in inconsistent interpretation of performance parameters, impeding progress in the field. This Perspective recommends key metrics and experimental details, which are suggested for reporting in ...
Jessie A. Posar +8 more
wiley +1 more source
Visualizing the near-field distribution of microwave field in a monopole antenna is very important for antenna design and manufacture. However, the traditional method of measuring antenna microwave near field distribution by mechanical scanning has some ...
Xuguang Jia +5 more
doaj +1 more source
In this paper, we investigate the possibility of measuring the purity of a quantum state (and the overlap between two quantum states) within a minimal model where the measurement device is minimally composed.
Kimura, Gen +2 more
core +1 more source
Novel ferrocene derivatives (e.g., FcPhc2) are used as an ultrathin layer hole‐blocking layer, reducing hole injection from the Ag contact. This results in an ultralow noise spectral density of 1.2 × 10−14 A Hz−1/2, and a high specific detectivity of 8.1 × 1012 Jones at −0.5 V.
Eunyoung Hong +16 more
wiley +1 more source

