Results 61 to 70 of about 271 (169)
The variations of significant energetic and exergetic performance parameters of automobile air conditioning systems operated in cooling mode for refrigerants R1234yf, R1234ze(e), R152a, R430A and R440A, which can be used as alternatives to R134a, were ...
Murat Hoşöz, Eren Kabak
doaj +1 more source
The Organic Rankine Cycle (ORC) is commonly accepted as a viable technology to convert from low to medium temperature geothermal energy into electrical energy.
Nenad Mustapić +3 more
doaj +1 more source
Motor cooling is key to the reliable operation of centrifugal refrigeration compressors with gas bearings. A mathematical model of a centrifugal refrigeration compressor with gas bearings was devised, and the influences of different refrigerants on the ...
Liu Yiteng +4 more
doaj
Investigation of Frictional Pressure Drop During Flow Boiling of R1234ze(E) in Horizontal Tub
Recently, more attention have been paid to the new refrigerant R1234ze(E), which is supposed to be the most promising alternative of R134a in heat pump system. In this paper, the saturated flow boiling frictional pressure drops characteristics of R1234ze(
Qiu Jinyou +5 more
doaj
This study evaluates two low-global warming potential (low-GWP) refrigerants—R1233zd(E) and R1234ze(Z)—for use in solar ejector refrigeration systems. A steady-state thermodynamic model is developed to compare their performance with baseline R134a across
Zhao Cheng-ming +4 more
doaj +1 more source
Due to its environmental benefits, CO2 shows great potential in refrigeration systems. However, a basic CO2 transcritical (BCT) refrigeration system used for airconditioning in buildings might generate massive indirect carbon emissions for its low COP ...
Yijian He +4 more
doaj +1 more source
SLE for the carbon dioxide +trans-1,3,3,3-tetrafluoropropene
A built experimental set-up was employed for the estimation of the solid-liquid equilibria of alternative refrigerants systems. The behavior of carbon dioxide + 1,3,3,3-tetrafluoropropene (CO2 + R1234ze(E)) was measured down to temperatures of 160.0 K ...
Di Nicola G. +3 more
doaj +1 more source
This paper proposes and simulates a desiccant air cooling system integrated with a vapor compression cooling unit and a heat recovery unit for an office building in Çanakkale, Turkey, during the summer season. The required electrical energy for equipment
Kamil Neyfel Çerçi +3 more
doaj +1 more source
A Dual-Path Pulse-Echo Instrument for Liquid-Phase Speed of Sound and Measurements on p-Xylene and Four Halogenated-Olefin Refrigerants [R1234yf, R1234ze(E), R1233zd(E), and R1336mzz(Z)]. [PDF]
McLinden MO, Perkins RA.
europepmc +1 more source
This paper presents local condensation Heat Transfer Coefficients (HTCs) and temperature profiles of R134a and three low-GWP replacements, R1234yf, R1234ze(E), and R152a, within Brazed Plate Heat Exchangers (BPHEs).
Giovanni A. Longo, Claudio Zilio
doaj +1 more source