R134a And Various Mixtures of R22/R134a as an Alternative to R22 in Vapour Compression Heat Pumps
Energy Conversion and Management, 2004Abstract The performance of an air to water vapor compression heat pump has been investigated experimentally. The main purpose of this study was to investigate the possibilities of using R134a as a working fluid to replace R22 for vapor compression heat pumps.
Ö Çomakli
exaly +4 more sources
Fluid Phase Equilibria, 1992
Abstract Thermal conductivity measurements are reported for the alternative refrigerant 1,1,1,2-tetrafluoroethane (R134a). These measurements were made over the temperature range from 200 to 390 K at pressures to 70 MPa. Data are reported for the liquid, vapor, and supercritical fluid phases.
C A Nieto de Castro
exaly +2 more sources
Abstract Thermal conductivity measurements are reported for the alternative refrigerant 1,1,1,2-tetrafluoroethane (R134a). These measurements were made over the temperature range from 200 to 390 K at pressures to 70 MPa. Data are reported for the liquid, vapor, and supercritical fluid phases.
C A Nieto de Castro
exaly +2 more sources
Energy evaluation of drop-in replacements for R134a in cascade CO2/R134a refrigeration units.
The energy performance of CO2 standard booster systems is limited in countries with high ambient temperatures to replace R404A direct expansion architectures. Therefore, cascade refrigeration systems with CO2 in the low-pressure stage can be considered.
MAKHNATCH P. +2 more
openaire +2 more sources
Removal of R134a from air/R134a mixture based on cryogenic condensation method
2021 IEEE 16th Conference on Industrial Electronics and Applications (ICIEA), 2021The emission of greenhouse gases is aggravating the global warming. Nowadays, R134a is widely used in refrigeration engineering, and its globe warming potential (GWP) is relatively high (1301). So, it is imperative to recover the R134a in refrigerating devices, and prevent it from being released to the atmosphere.
Boshi Shao +5 more
openaire +1 more source
International Journal of Refrigeration, 2020
Abstract This paper presents the results of an experimental investigation on pressure drop characteristics for R134a and R134a-lubricant mixtures in multiport flat tubes (MPFT). An experimental facility has been set up, carefully validated and used to determine the pressure drop value in the two-phase flow regime inside extruded MPFT with hydraulic ...
Paul Knipper +4 more
openaire +1 more source
Abstract This paper presents the results of an experimental investigation on pressure drop characteristics for R134a and R134a-lubricant mixtures in multiport flat tubes (MPFT). An experimental facility has been set up, carefully validated and used to determine the pressure drop value in the two-phase flow regime inside extruded MPFT with hydraulic ...
Paul Knipper +4 more
openaire +1 more source
Experimental Analysis of R1234yf as a Drop-In Replacement for R134a in a Vapor Compression System [PDF]
This paper presents an experimental analysis of a vapor compression system using R1234yf as a drop-in replacement for R134a. In this work, we compare the energy performance of both refrigerants, R134a and R1234yf, in a monitored vapor compression system ...
Joaquín Navarro-Esbrí +2 more
exaly +2 more sources
Thermophysical properties of refrigerant R134a
International Journal of Refrigeration, 1992Abstract Experimental results of measurements of the thermodynamic and transport properties of refrigerant R134a are presented for the temperature range 240–400 K and pressures up to 89 bar. The thermal properties of the saturated refrigerant were also determined. The results from this study showed that the dependence of viscosity on temperature near
G.K Lavrenchenko +3 more
openaire +1 more source
Experimental densities for compressed R134a
International Journal of Refrigeration, 1992Abstract This paper reports densities of compressed R134a (1,1,1,2-tetrafluoroethane) determined by using a contiuously weighed pycnometer at 20 K intervals between 180 and 380 K at pressures from slightly greater than the vapour pressure to 70 MPa. The results are accurate to within ±0.1%. Saturated liquid densities derived by extrapolation from the
H Hou, J.C Holste, B.E Gammon, K.N Marsh
openaire +1 more source
International Journal of Heat and Mass Transfer, 2010
zbMATH Open Web Interface contents unavailable due to conflicting licenses.
Suresh, M., Mani, A.
openaire +1 more source
zbMATH Open Web Interface contents unavailable due to conflicting licenses.
Suresh, M., Mani, A.
openaire +1 more source