Results 61 to 70 of about 7,149 (147)
ABSTRACT Objectives Cryogen spray cooling (CSC) is critical for protecting the epidermis during laser dermatologic procedures. The widely used cryogen, R134a, has a high global warming potential (GWP), motivating interest in environmentally favorable alternatives such as HFO‐1234ze.
Wangcun Jia +13 more
wiley +1 more source
Küresel ısınma Dünya gündeminin ana konularından birisidir. Dolayısıyla, soğutucu akışkanların çevresel etkilerini azaltmak için birçok çalışma ve düzenleme yapılmaktadır.
Abdullah Yıldız, Ragıp Yıldırım
doaj +1 more source
ABSTRACT The growing impacts of climate change and energy scarcity demand environmentally sustainable refrigeration solutions. This study investigates eco‐friendly refrigerants (R152a, R290 and R600a) and their optimized ternary mixture as alternatives to R134a. Four blend compositions were analysed using experimental testing and REFPROP 10.0 modelling
M. Periyasamy, P. Senthilkumar
wiley +1 more source
Thermally Optimized Engineering of a Battery Pack for Racing Cars
A time‐dependent CFD analysis compares six cooling architectures for a Formula student Li‐ion battery pack built on a metallic finned frame. A multi‐parametric single‐objective function merges thermal and structural metrics to identify the optimal trade‐off between performance and compactness, highlighting the potential of hybrid liquid–PCM systems ...
Nicolò Zatta +3 more
wiley +1 more source
ABSTRACT This study investigates binary zeotropic mixtures of R744 (CO₂) blended with eco‐friendly refrigerants for medium‐high temperature heat pumps, comparing them with conventional R744/R134a systems. All mixtures meet 60–80 K temperature lift requirements under low‐temperature conditions. A genetic algorithm optimized system parameters using fixed
Lingling Sun +6 more
wiley +1 more source
This study presents a novel next‐generation solar‐tower multigeneration plant that integrates a heliostat field with molten‐salt thermal‐energy storage (TES), a triple‐pressure reheat Rankine cycle, an organic Rankine cycle (ORC) using isobutane, a Kalina cycle with ammonia–water mixture, a single‐effect LiBr‐water absorption chiller, a vapor ...
Seyed Saeed Razavian, Mojtaba Babaelahi
wiley +1 more source
This study evaluates a renewable‐energy‐based system consisting of 300 m2 of parabolic trough solar collectors (PTSCs), a low‐temperature geothermal source (62°C), an Organic Rankine Cycle (ORC) using R134a as the working fluid, and a proton exchange membrane (PEM) electrolyzer for hydrogen production.
Ayhan Atiz, Cheng Du
wiley +1 more source
R134a-DMF absorption heat pump unit is an energy-saving heat pump unit that can utilize renewable energy, and has great potential in the refrigeration and heating fields of urban and rural areas.
Zhaoyi Zhuang +4 more
doaj +1 more source
Comparative Research on Performances of R516A and R134a in Water-Cooled Chillers
R516A is one of the new substitutes for R134a refrigerant in water-cooled chillers. The COP (coefficient of performance) and discharge temperatures of R516A and R134a are compared through a single-stage vapor compression cycle. Under nominal and variable
Li Xiongya, Hua Xue, Guo Xiaolin
doaj
Two-Phase Flow Development of R134a in a Horizontal Pipe: Computational Investigation
To improve the performance of vapor compression refrigeration systems that use vertical gravitational flash tank separators, the liquid separation efficiency of the vertical gravitational flash tank separator requires to be approved.
Saleh, Khalid +11 more
core +1 more source