Results 111 to 120 of about 577 (215)
Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka+8 more
wiley +1 more source
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka+6 more
wiley +1 more source
Closing the gap in plan quality: Leveraging deep‐learning dose prediction for adaptive radiotherapy
Abstract Purpose Balancing quality and efficiency has been a challenge for online adaptive therapy. Most systems start the online re‐optimization with the original planning goals. While some systems allow planners to modify the planning goals, achieving a high‐quality plan within time constraints remains a common barrier.
Sean J. Domal+9 more
wiley +1 more source
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki+9 more
wiley +1 more source
Abstract Purpose Studies on deep learning dose prediction increasingly focus on 3D models with multiple input channels and data augmentation, which increases the training time and thus also the environmental burden and hampers the ease of re‐training. Here we compare 2D and 3D U‐Net models with clinical accepted plans to evaluate the appropriateness of
Rosalie Klarenberg+2 more
wiley +1 more source
Abstract Background Acceleration treatment (AT) is a novel treatment planning parameter introduced in the tomotherapy‐dedicated treatment planning system, Precision. This study explores the effects of AT on tomotherapy plans using helical (TomoHelical) and direct (TomoDirect) irradiation techniques.
Ryosuke Shirata+9 more
wiley +1 more source
Dose rate correction of a diode array for universal wedge field dosimetric verification
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen+6 more
wiley +1 more source
Abstract Purpose This study evaluates the technical feasibility of adapting a surface monitoring system, designed for conventional four‐dimensional computed tomography (4DCT), to an intelligent, breathing‐adapted 4DCT and examines its potential to expand the currently limited range of supported surrogate systems.
Niklas Lackner+4 more
wiley +1 more source
Abstract This study compared three Brainlab thermoplastic masks—Cranial 4pi basic, stereotactic (Close Mask V2), and open‐face—to see how well they limited head movement during Stereotactic Radiosurgery (SRS). Using a head phantom, we tested rotational movements (pitch, yaw, and roll) and measured displacements with the ExacTrac system.
Iris Pasion Apale+2 more
wiley +1 more source
Abstract Purpose The purpose of the present study was to evaluate the impact of bone relative electron density (rED) assignment on radiotherapy planning for the abdominal region. Methods Twenty patients who received abdominal radiotherapy using MR‐Linac and underwent magnetic resonance imaging (MRI) and computed tomography (CT) simulation were analyzed.
Kota Abe+4 more
wiley +1 more source