Results 11 to 20 of about 986 (262)
Modeling of application the FACTS devices on the example of power system of United Power System of Center [PDF]
This paper considers installation of a flexible AC transmission system (FACTS) device on the 500 kV line of substation (SS) Belozerskaya - SS Vologodskaya of the United Power System of Center.
Udaratin Alexey +3 more
doaj +1 more source
WAYS TO IMPROVE THE EFFICIENCY OF ELECTRIC SUBMERSIBLE PUMP UNITS FOR OIL PRODUCTION
The relevance of the research is conditioned by the need to verify the data of «submersible motor – downhole compensator» node obtained on the simulation model with the results of bench tests.
Vladimir A. Kopyrin +2 more
doaj +1 more source
EVALUATION OF TOTAL COST OF POSSESSING THE ELECTRIC CENTRIFUGAL PUMP WITH SUBMERSIBLE COMPENSATOR
The relevance.Today, the production of oil is generally carried out in a mechanized manner, which is sufficiently energy intensive. In the cost structure of oil production, the value of electric power is from 30 to 35 % of the value. Considering that the
Vladimir A. Kopyrin +6 more
doaj +1 more source
REACTIVE POWER. REACTIVE POWER COMPENSATION.
It is possible to economically save electricity by compensating reactive energy in electric motors. Below we will consider the power of the capacitor device to compensate the reactive power through the simplest calculations.
openaire +1 more source
Rao S. Thallam Salt River Project 18.1 The Need for Reactive Power Compensation 18-1 Shunt Reactive Power Compensation . Shunt Capacitors 18.2 Application of Shunt Capacitor Banks in Distribution Systems—A Utility Perspective 18-2 18.3 Static VAR Control 18-3 Description of SVC . How Does SVC Work?
Rao S. Thallam, Géza Joós
+5 more sources
In a three-phase four-wire distribution network, the load unbalance can be compensated by the use of an unbalanced three-phase reactive compensator, containing six single-phase coils and capacitors, grouped into two distinct circuits, having Yn and delta
Adrian Pană +2 more
doaj +1 more source
Modelling of emergency modes with FACTS devices installed [PDF]
This paper considers installation of FACTS devices in a 500 kV line of substation (SS) Belozerskaya SS Vologodskaya. Three FACTS devices in emergency mode were modelled: a static reactive power compensator (STATCOM), a static synchronous series ...
Udaratin Alexey +4 more
doaj +1 more source
Optimization of reactive power consumption regimes by the electric centrifugal pumps installations
The purpose of the article is to determine the optimal parameters inside the downhole compensator of the reactive power at which minimization consumption of active power is provided.
Kopyrin Vladimir +2 more
doaj +1 more source
IMITATION MODELING OF THE HYBRID VAR COMPENSATOR
Purpose. Study of the effectiveness of the hybrid VAR compensator, which consists of series-connected capacitor bank (CB) with discrete regulation and active filter of higher harmonics, with different control strategies, under asymmetrical and / or non ...
O.S. Savenko +2 more
doaj +1 more source
To increase the electrical power quality, in the last decades, an intense development in the last decades of high-performance equipment built as advanced power electronics applications, such as the compensators from Switching Power Converter category ...
Adrian Pană +2 more
doaj +1 more source