Reliability Evaluation of Power System SVC Types Using a Markov Chain [PDF]

open access: yesJournal of Intelligent Procedures in Electrical Technology, 2015
Static reactive power compensator (SVC) plays an important role in power system reliability stems. In evaluations of reliability, only reactive power is considered as a constraint network is placed in the SVC Brrsy‌Ha impact on power system reliability ...
Ali Behdan, Bahador Fani, Ehsan Adib
doaj  

An optimal reactive power control scheme for rectifying station considering the coordination control of low-voltage reactor and AC system

open access: yesThe Journal of Engineering, 2019
When rectifier station of line-commutated converter based high-voltage direct transmission current has power fluctuations running at large load, reactive power compensator controlled in groups at rectifying station are switched frequently.
Zijia Hui   +5 more
doaj   +1 more source

New mathematical model for analysing three-phase controlled rectifier using switching functions [PDF]

open access: yes, 2010
This paper is a postprint of a paper submitted to and accepted for publication in IET Power Electronics and is subject to Institution of Engineering and Technology Copyright. The copy of record is available at IET Digital Library.The aim of this study is
Marouchos, C   +5 more
core   +1 more source

ON THE ISSUE OF USING DOWNHOLE REACTIVE POWER COMPENSATORS

open access: yesИзвестия высших учебных заведений: Нефть и газ, 2015
The article discusses the possibility of using the downhole reactive power compensators as a part of electric submersible pumps. The analysis of the existing reactive power compensators was made and the shortcomings of the technical solutions were ...
O. V. Smirnov, V. A. Kopyrin
doaj   +1 more source

СURRENT FILTERING IN A THREE-PHASE THREE-WIRE POWER SYSTEM AT ASYMMETRIC SINUSOIDAL VOLTAGES

open access: yesElectrical engineering & Electromechanics, 2018
Purpose. Investigation of the optimal current distribution between source, shunt active filter and reactive compensator of a three-phase three-wire system that provides consumption of a sinusoidal symmetric current under asymmetric source voltages with ...
M. Yu. Artemenko   +2 more
doaj   +1 more source

Fault Models of Inverter-Interfaced Distributed Generators: Experimental Verification and Application to Fault Analysis [PDF]

open access: yes, 2011
23/04/13 meb.
Plet, CA   +7 more
core   +1 more source

Cost based reactive power participation for voltage control in multi units based isolated hybrid power system

open access: yesJournal of Electrical Systems and Information Technology, 2016
Multi units of wind and diesel based generators in isolated hybrid power system have technical and operational advantages over single units system. They require dynamic reactive power compensation for fast recovery of voltage under load and input changes.
Nitin Kumar Saxena, Ashwani Kumar
doaj   +1 more source

Interpreting the effects of DNA polymerase variants at the structural level

open access: yesMolecular Oncology, EarlyView.
Using MAVISp and molecular dynamics simulations, we analyzed over 60 000 missense variants in POLE and POLD1 from ClinVar, COSMIC, cBioPortal, and saturation mutagenesis. Identified mechanistic indicators, including stability, binding, and long‐range, enable structural interpretation, providing ACMG‐like evidence for possible reclassification of VUS ...
Matteo Arnaudi   +7 more
wiley   +1 more source

Experimental Validation of the DSTATCOM Based on SiC-MOSFET Multilevel Converter for Reactive Power Compensation [PDF]

open access: yesJournal of Systemics, Cybernetics and Informatics, 2020
Power quality problems are associated, among other things, with the reactive power generated at the AC side in distribution systems. In this regard, the three-phase distribution static compensator is becoming a viable alternative in order to achieve ...
Raúl Gregor   +4 more
doaj  

Comparative Study of SVC and STATCOM Reactive Power Compensation for Prosumer Microgrids With DFIG-Based Wind Farm Integration

open access: yesIEEE Access, 2020
Uncertainties of renewable energy sources like wind power are one of the considerable challenges of prosumer microgrids. To meet the grid codes requirements regarding the voltage stability of wind farm integration, finding the balance between providing ...