Results 21 to 30 of about 385,595 (210)
Deep residual neural network for EMI event classification using bispectrum representation [PDF]
This paper presents a novel method for condition monitoring of High Voltage (HV) power plant equipment through analysis of discharge signals. These discharge signals are measured using the Electromagnetic Interference (EMI) method and processed using ...
Boreham, Philip +5 more
core +2 more sources
High Altitude test of RPCs for the ARGO-YBJ experiment [PDF]
A 50 m**2 RPC carpet was operated at the YangBaJing Cosmic Ray Laboratory (Tibet) located 4300 m a.s.l. The performance of RPCs in detecting Extensive Air Showers was studied.
A. MANGANO +105 more
core +2 more sources
Networks of Coevolving Residues in Voltage Sensor Domains [PDF]
Voltage sensors (VSDs) are ubiquitous protein domains acting as transducers of transmembrane electric signals. Owing to the fundamental nature of this task, VSDs emerged before the division between prokaryotes and eukaryotes and are accordingly found in extant genes from long-diverged phylogenetic lineages.
Carnevale, Vincenzo +3 more
openaire +1 more source
A System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance Index
In order to systematically compare the voltage sag severity of different regions, a system method is proposed to assess grid voltage sag severity. The method obtains the time duration intervals through cluster analysis, and gets the medians of residual ...
Qing ZHONG +4 more
doaj +1 more source
Residual Voltage Tests of 4.5 kV Metal Oxide Surge Arrester
Overvoltages can cause various malfunctions in electrical power systems and high voltage facilities. Metal oxide surge arresters (MOSAs) are used to prevent overvoltage-related malfunctions in electrical power systems and high voltage facilities. MOSAs protect the system from high amplitude currents by conducting overvoltage-induced discharge currents ...
Tunç, Emre, Fidan, Murat
openaire +2 more sources
Design and analysis of low-voltage residual current operated protective device
In view of problem that current residual current operated protective device could easily lead to serious interphase short circuit fault after single-phase leakage, the paper analyzed operating characteristics of a novel residual current operated ...
ZHANG Xiuhua
doaj +1 more source
Residues Involved in Cx26 Hemichannels Voltage Dependent Gating [PDF]
The most well-known role of Connexins (Cxs) is to communicate the cytoplasm of two adjacent cells forming a gap junction channel in the apposition zone. On the other hand, Cxs form the so called “hemichannels”, a fully functional voltage-gated non-selective ion channel, which present two gating mechanism called “slow” and “fast” gating.
Pinto, Bernardo I. +5 more
openaire +1 more source
Influence of Inhomogeneous Residual Charges on the Stress of Filter Capacitor Components
In recent years, the serious vibration and noise problem of high voltage filter capacitor has become the primary problem of noise reduction in high voltage direct current (HVDC) converter station.
Pengning Zhang, Bofan Li, Wei Li, Lin Li
doaj +1 more source
Emergence of domains and nonlinear transport in the zero-resistance state
We study transport in the domain state, the so-called zero-resistance state, that emerges in a two-dimensional electron system in which the combined action of microwave radiation and magnetic field produces a negative absolute conductivity.
Dmitriev, I. A. +3 more
core +1 more source
Characterization of an embedded RF-MEMS switch [PDF]
An RF-MEMS capacitive switch for mm-wave integrated circuits, embedded in the BEOL of 0.25μm BiCMOS process, has been characterized. First, a mechanical model based on Finite-Element-Method (FEM) was developed by taking the residual stress of the thin ...
Ehwald, K. E. +10 more
core +1 more source