Results 91 to 100 of about 261,095 (203)
Lifestyle modification in atrial fibrillation: Mechanisms, phenotypes and ablation outcomes
Abstract Atrial fibrillation (AF) is the most prevalent sustained cardiac arrhythmia and is associated with significant morbidity, mortality and healthcare utilization. Catheter ablation is increasingly used as a rhythm‐control intervention for patients with symptomatic paroxysmal and persistent AF, yet recurrence rates remain suboptimal.
Konstantinos Grigoriou +11 more
wiley +1 more source
Abstract figure legend Young, healthy males and females completed an incremental running test, demonstrating a progressive increase in middle cerebral artery blood velocity (MCAv) up to maximal exercise despite reductions in end‐tidal CO2. To investigate the underlying mechanism, foot‐strike timing was synchronized to the diastolic phase of the cardiac
Lydia L. Simpson +5 more
wiley +1 more source
Strategies for increasing the operating frequency range of vibration energy harvesters: a review
This paper reviews possible strategies to increase the operational frequency range of vibration-based micro-generators. Most vibration-based micro-generators are spring-mass-damper systems which generate maximum power when the resonant frequency of the ...
Beeby, Steve, Zhu, Dibin, Tudor, John
core +1 more source
Cross‐Entropy of Power Spectral Density Function: A Modal Identification Framework
ABSTRACT The power spectral density (PSD) function of measured structural response contains a significant amount of information, including the modal parameters (natural frequencies, damping ratios). Output‐only system identification or modal identification technique can be used for extracting such modal parameters from the measured response or its ...
Su‐Hong Kim +3 more
wiley +1 more source
Design and Analysis of Silicon Resonant Accelerometer
In this study, we present an approach for micromechanical resonant accelerometer design, structural optimization and testing method of a kind of resonant accelerometer which is excited by the electrostatic force and detected by the change of capacitance.
Jing Li, Shangchun Fan, Zhanshe Guo
openaire +1 more source
An Ultra-High Resolution Resonant MEMS Accelerometer
This paper reports initial results on the implementation of a high-resolution resonant MEMS accelerometer with a noise floor of 17.8\text{ng}/\surd{}\text{Hz} and a bias stability of 17.5ng with a differential frequency readout configuration.
Zhao, C +7 more
core
ABSTRACT We present a hybrid interpretable Physics‐Informed Neural Network Long‐Short Term Memory (Hybrid PINN LSTM) framework for predicting the seismic response of rocking blocks. Existing analytical models rely on uncertain idealizations, while purely data‐driven and machine‐learning approaches lack physical consistency and interpretability.
Shirley Shen +1 more
wiley +1 more source
A Micromachined Silicon-on-Glass Accelerometer with an Optimized Comb Finger Gap Arrangement
This paper reports the design, fabrication, and characterization of a MEMS capacitive accelerometer with an asymmetrical comb finger arrangement. By optimizing the ratio of the gaps of a rotor finger to its two adjacent stator fingers, the sensitivity of
Jiacheng Li +5 more
doaj +1 more source
MEMS resonant accelerometer having improved electrical characteristics
A MEMS resonant accelerometer is disclosed, having: a proof mass coupled to a first anchoring region via a first elastic element so as to be free to move along a sensing axis in response to an external acceleration; and a first resonant element ...
B. Simoni +2 more
core
Physical Activity and Adiposity Markers at Older Ages: Accelerometer Vs Questionnaire Data [PDF]
Physical activity is critically important for successful aging, but its effect on adiposity markers at older ages is unclear as much of the evidence comes from self-reported data on physical activity.
van Hees, Vincent , +19 more
core +1 more source

