Results 131 to 140 of about 2,241 (208)

Toward a Robotic Future: Generational Shifts in the Acceptance of Social Robots on Brazilian Coffee Farms

open access: yesExpert Systems, Volume 43, Issue 6, June 2026.
ABSTRACT The selective migration of young people to urban centres has resulted in an ageing workforce within the Brazilian coffee sector, creating a growing demand for solutions that aid producers in crop management routines. Coffee production, the fourth largest in terms of gross national agricultural revenue, can benefit from technological support ...
Danilo Fernandes da Silva   +5 more
wiley   +1 more source

In vivo quantification of mitochondrial O2 affinity in human skeletal muscle using 1H‐magnetic resonance spectroscopy of deoxy‐myoglobin

open access: yesThe Journal of Physiology, Volume 604, Issue 12, Page 4876-4888, 15 June 2026.
Abstract figure legend This graphical abstract illustrates a novel, non‐invasive approach to quantify mitochondrial oxygen (O2) affinity in vivo in human skeletal muscle using 1H magnetic resonance spectroscopy (1H‐MRS) of deoxymyoglobin (dMb). During brief arterial occlusion, dMb kinetics were used to simultaneously estimate intracellular oxygen ...
Muhammet Enes Erol   +8 more
wiley   +1 more source

Improved detection structure for a z-axis resonant accelerometer

open access: yes, 2012
The present invention relates to an improved detection structure for a resonant accelerometer with vertical axis (so-called "z-axis"), of a MEMS (microelectromechanical system) or NEMS (nanoelectromechanical system) type, in particular one capable of ...
S. Zerbini   +2 more
core  

Methods of frequency tuning vibration based micro-generator

open access: yes, 2009
A vibration based micro-generator is an energy harvesting device that couples a certain transduction mechanism to the ambient vibration and converts mechanical energy to electrical energy.
Zhu, Dibin
core  

A Resonant MEMS Accelerometer Utilizing AC Polarization

open access: yes, 2018
In this paper, we present a resonant MEMS accelerometer (RXL) using AC polarization voltage as an alternative to the existing DC polarization schemes. By making full use of the intrinsic frequency mixing property of a parallel plate capacitive transducer,
Zhao, C   +7 more
core  

Structure Design Optimization of a Differential Capacitive MEMS Accelerometer Based on a Multi-Objective Elitist Genetic Algorithm. [PDF]

open access: yesMicromachines (Basel)
Yang D   +10 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy