Flexible composite suppression method for ground arc in resonant grounding system

open access: yesHigh Voltage, 2023
A current‐voltage composite controller for an arc suppression inverter is designed. The current and voltage at the fault point are reduced by injecting current and regulating the neutral point voltage to completely eliminate the risk of fire and ...
Jianzhang You   +3 more
doaj   +2 more sources

A novel approach for high impedance fault detection in resonant grounding systems based on statistical characteristics [PDF]

open access: yesScientific Reports
High impedance faults (HIF) in the resonant grounding system of distribution networks pose significant challenges for traditional protection devices, which often fail to detect and eliminate these faults promptly. The difficulty in setting an appropriate
Qinglin Meng   +4 more
doaj   +2 more sources

Ground Fault Detection Based on Fault Data Stitching and Image Generation of Resonant Grounding Distribution Systems

open access: yesEnergies, 2023
Fast and accurate fault detection is important for the long term, stable operation of the distribution network. For the resonant grounding system, the fault signal features extraction difficulties, and the existing detection method’s accuracy is not high.
Xianglun Nie   +6 more
doaj   +2 more sources

Simulation Analysis of Single-phase Grounding Fault of Resonant Grounding System

open access: yesGong-kuang zidonghua, 2012
For problem of difficult line selection caused by small current of fault line with uncertain direction when single-phase grounding fault happens in resonant grounding system, the paper theoretically analyzed change law of zero-sequence voltage and zero ...
LI Hui, TANG Yi, SUN Chang-qing
doaj   +1 more source

Research on Magnetically Coupled Resonant Detection Method for Breakpoint of Four Mesh Grounding Grid

open access: yesCES Transactions on Electrical Machines and Systems, 2023
Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid. But the method can only detect breakpoints of a single mesh grounding grid at present.
Weihua Chen   +3 more
doaj   +1 more source

Faulty Section Location Method Based on Dynamic Time Warping Distance in a Resonant Grounding System

open access: yesEnergies, 2022
When a single-phase grounding fault occurs in a resonant grounding system, the determination of the fault location remains a significant challenge due to the small fault current and the instability of the grounding arc.
Yu He   +6 more
doaj   +1 more source

Fault location method combining transient mutation and dynamic time warping algorithm for grounding system

open access: yesEnergy Reports, 2023
In the urban distribution network, due to the wide application of underground cables, the traditional resonant grounding system has gradually been unable to match the increasing fault current amplitude, real-time compensation and harmonic component ...
Kangli Liu   +3 more
doaj   +1 more source

Combined line selection of single-phase grounding faults considering harmonic injection of distributed powers

open access: yes电力工程技术, 2023
With the improvement of the requirements for the safe operation of distribution network lines, the harmonics injected by distributed power generation make the existing line selection methods ineffective, and the fault line selection method with a single ...
LI Yan   +4 more
doaj   +1 more source

Harmonic Resonance Stability of Aeronautical Ground Lighting Systems [PDF]

open access: yesIEEE Journal of Emerging and Selected Topics in Power Electronics, 2018
Aeronautical ground lighting (AGL) systems assist aircraft pilots in airport operations. These systems are singlephase series circuits where constant current regulators (CCRs) feed luminaires with an adjustable rms current. CCRs are voltage source converters (VSCs) which may cause harmonic resonance instabilities when their control interacts with ...
Vidal, Daniel   +2 more
openaire   +4 more sources

Single-Line-to-Ground Fault Location in Resonant Grounded Systems Based on Fault Distortions [PDF]

open access: yesIEEE Access, 2021
Under single-line-to-ground (SLG) faults, the voltages and currents in resonant grounded systems will inevitably be distorted. To locate the faults quickly and accurately, this paper proposes a location method based on fault distortions. The faulty phase is firstly detected according to the first SLG fault feature below, and then the faulty feeder and ...
Yougen Chen   +3 more
openaire   +2 more sources