This study presents an integrated proof‐of‐concept robotic platform for targeted delivery applications. A hybrid magnetic actuation system achieves single‐input (z) multistate stabilization (x, y, ϕ, and θ) for precise capsule transport with submillimeter positioning accuracy.
Sejun Park +6 more
wiley +1 more source
Recent advances: Augmented reality, robotics, and navigation in oculoplasty and orbit. [PDF]
Gaur N, Neha N.
europepmc +1 more source
This work presents an inchworm‐like dual‐balloon‐assisted colonoscopic robot (IDCR) based on a rod‐driven two‐segment continuum section. The IDCR enables the active straightening of the sigmoid colon through an inchworm‐like locomotion strategy, thereby avoiding loop formation.
Dezhi Song +4 more
wiley +1 more source
A Multidimensional Perspective on Network Conditions in Telesurgery
A multidimensional framework systematically evaluates how combined network impairments influence telesurgical performance. By jointly analyzing latency, jitter, bandwidth, and packet loss, the proposed methodology identifies relevant network condition parameters and their interactions, supporting the design of reliable and safe telesurgical systems ...
Florian Heemeyer +4 more
wiley +1 more source
Contactless robotic system for linear catheter advancement using magnetic actuation. [PDF]
Sianca LP, Stallkamp J, Moviglia J.
europepmc +1 more source
Fast, Strong Capillary Liquid Metal Muscles
Capillary liquid metal muscles (CLMMs) harness the exceptionally high and electrochemically tunable surface tension of gallium‐based liquid metals (e.g., EGaIn) to generate mechanical work. Confinement within microchannels maximizes surface‐energy conversion, enabling high force, ultrafast response (<25 ms), low‐voltage operation (<10 V), and ...
Tim Cole +8 more
wiley +1 more source
3D- and 4D-Printed Nano-Enabled Soft Robots for Cancer Diagnosis and Therapy: Materials, Manufacturing, Image Guidance, and Translational Validation. [PDF]
Han YR, Lee SB.
europepmc +1 more source
3D Closed‐Loop Navigation of Magnetic Microswimmers Using Vision‐Derived Depth Feedback
A planar magnetic microswimmer is navigated in three dimensions under a standard microscope. Image defocus supplies a real‐time depth cue, and model‐predictive control with A* planning steers the body on surfaces and in free swimming. Axial position is regulated by propulsion alone, without magnetic field gradients or extra cameras.
Yasin Cagatay Duygu +2 more
wiley +1 more source
Artificial intelligence for vascular minimally invasive surgery: techniques, clinical integration, and challenges. [PDF]
Jiang C +9 more
europepmc +1 more source
Shape Sensing, Mapping, and Obstacle Avoidance of the Continuum Manipulator in Confined Environments
An integrated sensing framework combines capacitive sensors, IMU, and laser array sensor. The shape reconstruction is finished by backpropagation neural network. Accurate shape estimation (relative error of 1.04%) is maintained under a 110 g tip load, while a miniaturized VL6180X array enables local environmental reconstruction and reactive obstacle ...
Pengyuan Wang +9 more
wiley +1 more source