TGF-β1/IL-11/MEK/ERK signaling mediates senescence-associated pulmonary fibrosis in a stress-induced premature senescence model of Bmi-1 deficiency

open access: yesExperimental and Molecular Medicine, 2020
To study whether TGF-β1/IL-11/MEK/ERK (TIME) signaling mediates senescence-associated pulmonary fibrosis (SAPF) in Bmi-1-deficient (Bmi-1−/−) mice and determines the major downstream mediator of Bmi-1 and crosstalk between p16INK4a and reactive oxygen ...
Haiyun Chen   +13 more
doaj   +1 more source

Modeling and Experimental Validation of a Single-Phase Series Active Power Filter for Harmonic Voltage Reduction

open access: yesIEEE Access, 2019
Research advances on renewable energy systems have increased the interest in the use of isolated power supplies composed of power converters based on high-frequency transformers.
Lucas Frederico Jardim Meloni   +3 more
doaj   +1 more source

Optimization of Phase jump angle of Series Active Power Filter (SAPF)

open access: yesInternational Journal of Engineering Research, 2014
This paper deals with the optimization of phase jump angle of series active power filter by using particle swarm optimization technique and series active power filter compensates supply voltage distortions/unbalance, supply voltage harmonics in a view as such they do not reach at the load end with very low THD in load voltage.
P.Vasudeva Naidu   +2 more
openaire   +1 more source

Improvement of the Source Current Quality for a Shunt Active Power Filter Operating Using Hysteresis Technique with Stabilized Switching Frequency

open access: yesEnergies
Determining the current reference for a shunt active power filter (SAPF) can be carried out in many ways. Once the reference is determined, it can be shaped by SAPF switches with the use of pulse width modulation (PWM)/hysteresis control techniques ...
Andrzej Szromba
doaj   +1 more source

A Refined Self-Tuning Filter-Based Instantaneous Power Theory Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters under Non-sinusoidal Source Voltage Conditions

open access: yesEnergies, 2017
In this paper, a refined reference current generation algorithm based on instantaneous power (pq) theory is proposed, for operation of an indirect current controlled (ICC) three-level neutral-point diode clamped (NPC) inverter-based shunt active power ...
Yap Hoon   +3 more
doaj   +1 more source

Power Quality Improvement by Harmonic Reduction Using Three Phase Shunt Active Power Filter with p-q & d-q Current Control Strategy [PDF]

open access: yes, 2015
With the widespread use of power electronics devices such as rectifier, inverter etc. in power system causes serious problem relating to power quality. One of such problem is generation of current and voltage harmonics causing distortion of load waveform,
Bhadra , Dibyendu, Meena , Rajnish Kumar
core  

Development of Shunt Active Power Filter for Harmonic Reduction using Synchronous Reference Frame with Space Vector Pulse Width Modulation

open access: yesNigerian Journal of Technological Development, 2020
The work aims at development of Shunt Active Power Filter (SAPF) for harmonic reduction. The current harmonics are being caused by nonlinear characteristic of power electronics based equipments which increase power losses and in turn reduce power quality.
Sijuwade Akanni Akintade   +2 more
doaj  

A Lyapunov Stability Theory-Based Control Strategy for Three-Level Shunt Active Power Filter

open access: yesEnergies, 2017
The three-phase three-wire neutral-point-clamped shunt active power filter (NPC-SAPF), which most adopts classical closed-loop feedback control methods such as proportional-integral (PI), proportional-resonant (PR) and repetitive control, can only output
Yijia Cao   +4 more
doaj   +1 more source

Power Quality Comparative Analysis between UPF and SAPF

open access: yesJournal of Energy and Power Engineering, 2021
null Nicolae Badea   +2 more
openaire   +1 more source

DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter [PDF]

open access: yes, 2017
Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a ...
Mailah, Nashiren Farzilah   +2 more