Results 141 to 150 of about 56,939 (250)

On the Effect of Creep on Local Lattice Orientation in Single‐Crystal Ni‐Based Superalloy Microstructures

open access: yesAdvanced Engineering Materials, EarlyView.
During creep of a single‐crystal Ni‐based superalloy, the overall crystal orientation is observed to remain constant while the microstructure evolves. Despite the lack of macroscopic rotation, small (<1°) rotations are observed on the submicron size scale and are accommodated by counteracting rotations over the scale of several micrometers.
E. J. Payton   +3 more
wiley   +1 more source

Changes in Semen Analysis over Time: A Temporal Trend Analysis of 20 Years of Subfertile Non-Azoospermic Men. [PDF]

open access: yesWorld J Mens Health, 2023
Punjani N   +8 more
europepmc   +1 more source

Uniform Amorphization of Crystalline Silicon Surfaces Enabled by Deep Ultraviolet Femtosecond Laser Pulses

open access: yesAdvanced Engineering Materials, EarlyView.
Deep‐UV (258 nm) femtosecond pulses enable uniform amorphous silicon writing on Si(100)/(111) with a six‐fold larger fluence amorphization window than NIR methods. Optimized fluence and overlap yield 20–45 nm uniform and continuous amorphous layers. Microscopy shows sharp interfaces, and real‐time reflectivity reveals nanosecond melt–resolidification ...
Wissal Benali   +5 more
wiley   +1 more source

Impact of SARS-CoV-2 on the male reproductive tract: insights from semen analysis and cryopreservation. [PDF]

open access: yesJ Assist Reprod Genet
Giugliano S   +6 more
europepmc   +1 more source

The Sixth Edition of the WHO Manual for Human Semen Analysis: A Critical Review and SWOT Analysis. [PDF]

open access: yesLife (Basel), 2021
Boitrelle F   +9 more
europepmc   +1 more source

Superlubricity and Corrosion Inhibition Properties of Solvate Ionic Liquids in Hybrid Carbon Fiber Reinforced Plastic–Steel Interfaces

open access: yesAdvanced Engineering Materials, EarlyView.
Solvate ionic liquids lubrication reduced the coefficient of friction by ∼60% compared to dry sliding, reaching steady‐state values as low as 0.04–0.05. Corrosion weight‐loss measurements in 1 M HCl further demonstrated significant inhibition behavior, with only 100 ppm of [Li(G3)][TFSI] (∼68.5 μL/L) reducing corrosion‐product weight loss by 63 ...
Sameh Dabees   +6 more
wiley   +1 more source

Optimal timing for repeat semen analysis during male infertility evaluation. [PDF]

open access: yesF S Rep, 2021
Punjani N   +5 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy