Results 101 to 110 of about 30,870 (310)
Estimation and Modeling of the Full Well Capacity in Pinned Photodiode CMOS Image Sensors [PDF]
This letter presents a simple analytical model for the evaluation of the full well capacity (FWC) of pinned photodiode (PPD) CMOS image sensors depending on the operating conditions and on the pixel parameters.
Pelamatti, Alice +4 more
core +1 more source
Chamber‐specific decellularized extracellular matrices (ECMs) were developed, preserving native proteomic profiles of ventricular and atrial myocardium. These innate biochemical cues differentially modulate cardiomyocyte subtypes to drive engineered heart tissue development and function, highlighting the importance of incorporating regional ECM cues in
Dong Gyu Hwang +7 more
wiley +1 more source
Bioinspired Adaptive Sensors: A Review on Current Developments in Theory and Application
This review comprehensively summarizes the recent progress in the design and fabrication of sensory‐adaptation‐inspired devices and highlights their valuable applications in electronic skin, wearable electronics, and machine vision. The existing challenges and future directions are addressed in aspects such as device performance optimization ...
Guodong Gong +12 more
wiley +1 more source
With their significant features, the applications of complementary metal-oxidesemiconductor (CMOS) image sensors covers a very extensive range, from industrialautomation to traffic applications such as aiming systems, blind guidance, active/passiverange ...
Joe-Air Jiang +2 more
doaj
Low-frequency noise impact on CMOS image sensors [PDF]
CMOS image sensors are nowadays extensively used in imaging applications even for high-end applications. This is really possible thanks to a reduction of noise obtained, among others, by Correlated Double Sampling (CDS) readout.
Magnan, Pierre +1 more
core
Similarities Between Proton and Neutron Induced Dark Current Distribution in CMOS Image Sensors [PDF]
Several CMOS image sensors were exposed to neutron or proton beams (displacement damage dose range from 4 TeV/g to 1825 TeV/g) and their radiation-induced dark current distributions are compared.
Bardoux, A. +13 more
core +1 more source
The water permeability of amorphous carbon dots (CDs) is demonstrated by investigating their plasticization. Novel polyamide‐based and amorphous nanoparticles are synthesized by controlling their inner packing density. Water plasticization is evidenced by the decrease of the CDs glass transition temperature with increasing the hydration degree.
Elisa Sturabotti +8 more
wiley +1 more source
This paper proposes a novel charge-based Complementary Metal Oxide Semiconductor (CMOS) capacitive sensor for life science applications. Charge-based capacitance measurement (CBCM) has significantly attracted the attention of researchers for the design ...
Saghi Forouhi +2 more
doaj +1 more source
Development of CMOS sensors for electron microscopy
In this work, we show the design and preliminary characterization of an image sensor with 64x64 pixels and its associated hardware and software needed to use the chip. The aim of the chip is to be used as a sensor for TEM electron microscopy. First measurements were done using X-Rays to characterize the chip and to test the whole system (ASIC, Software,
Mateos, H. +3 more
openaire +2 more sources
Adaptive Sensor Response Correction Using Analog Filter Compatible with Digital Technology
An analog adaptive filter for response correction of a load cell sensor is presented. The filter employs only transistors and therefore it can be integrated using digital CMOS technology, which is suitable for System-on-Chip applications.
White, Neil M. +2 more
core