Results 41 to 50 of about 1,294,192 (244)
Shear connectors are one of the most important elements required for the composite construction. Composites structure usually fail at the shear between two structural elements i.e. steel and concrete.
Ghimire, Uspal
core
Thermomechanical fatigue tests of laser beam powder bed fusion (PBF‐LB) Inconel 718 show that the additively manufactured material reaches almost the lifetimes of conventionally‐rolled material under no‐dwell conditions. Introducing dwell times at the maximum temperature markedly reduces the lifetimes due to pronounced grain boundary sliding associated
Stefan Guth +6 more
wiley +1 more source
Copper‐based composites enhanced with carbon feature convenient mechanical properties and favorable electric conductivity. Processing via deformation and thermomechanical treatments can introduce advantageous microstructures further enhancing their performance. Herein, copper–graphene powder‐based composites are directly consolidated via rotary swaging
Radim Kocich +3 more
wiley +1 more source
Performance of wall panels with grouted sleeve connector under shear and bending [PDF]
This study discussed on the performances of concrete wall panels with grouted sleeve connector under shear and bending test. A substantial fraction of grouted sleeve connector behaviour has been investigated by several researchers from 90's century ...
Nur Izni, Mohd Khir
core +2 more sources
The function of the shear connector is to keep concrete plate oriental position. The installation of the shear connector will influence the distribution of the stress spread in unevenly on concrete plate.
Suyadi, Suyadi +2 more
core +1 more source
Experiments and thermophysical simulations were conducted to investigate the electron beam powder bed fusion electron beam (PBF‐EB/M) process for the γ′‐strengthened nickel‐based superalloy Inconel 738LC. The results demonstrate the impact of process‐induced microstructural variations on high‐temperature mechanical behavior, providing a basis for ...
Jan Niklas Petenati +11 more
wiley +1 more source
STRUCTURAL BEHAVIOR OF STEEL-CONCRETE-STEEL SANDWICH STRUCTURE WITH NEW TYPE OF SHEAR CONNECTORS
The aim of the current research is to investigate the structural behavior of steel-concrete-steel sandwich beams with a new suggested shear connectors. The shear connector was manufactured from deformed rebar in the form of stirrups.
Hayhder A. Abdul Razzaq, Nabeel A. Jasim
doaj +1 more source
Fretting corrosion and the reliability of multicontact connector terminals [PDF]
The harsh operating environment of the automotive application makes the semi-permanent connector susceptible to intermittent high contact resistance which eventually leads to failure. Fretting corrosion is often the cause of these failures.
Swingler, Jonathan +3 more
core +1 more source
Schematic representation of modes of microcrack nucleation, growth and temporary arrestment at different boundaries, with the criteria for crack propagation in three scenarios: (1) large notch, (2) defect/small sharp notch, and (3) long crack. This work revisits and integrates results on the fatigue behavior of advanced bainitic steels (in particular ...
Lucia Morales‐Rivas
wiley +1 more source
Elastic–Plastic Modeling and Experimental Characterization of Granular Jamming Actuators
Granular jamming enables rapid switching between soft and rigid mechanical states. Here, a reduced‐order elastic‐perfectly‐plastic beam framework captures pressure‐dependent loading, unloading, residual deformation, and hysteresis in jammed beams, while matching three‐point bending experiments across materials and geometries. The framework links design
Saheli Patel +2 more
wiley +1 more source

