Results 1 to 10 of about 6,315 (189)

Behavior of Tilted Angle Shear Connectors. [PDF]

open access: yesPLoS ONE, 2015
According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors.
Koosha Khorramian   +3 more
doaj   +8 more sources

Shear Capacity of C-Shaped and L-Shaped Angle Shear Connectors. [PDF]

open access: yesPLoS ONE, 2016
This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear ...
Farzad Tahmasbi   +4 more
doaj   +9 more sources

Analysis of Shear Performance of Multi-Bolt Shear Connectors. [PDF]

open access: yesMaterials (Basel), 2023
Bolt shear connectors used in prefabricated steel–concrete composite beams can be arranged into a group to enhance the construction efficiency, which will cause the multi-bolt effect and further affect the shear performance of bolt connectors. This paper developed three-dimensional finite element models of push-out specimens to investigate the shear ...
Xie R, Yang T, Li B, Liu S, Zhang Y.
europepmc   +5 more sources

Research on the Shear Behaviour of Composite Shear Connectors [PDF]

open access: yesBuildings, 2022
In order to make full use of the advantages of welded stud and perfobond rib shear connectors, a new type of composite shear connector is proposed. Studs are welded to the perforated steel plate of the PBL connectors.
Chengfeng Xue   +5 more
doaj   +3 more sources

Behaviour of Corroded Single Stud Shear Connectors. [PDF]

open access: yesMaterials (Basel), 2017
In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested.
Xue W, Chen J, Zhu JH.
europepmc   +6 more sources

Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure [PDF]

open access: yesMaterials, 2017
Shear connectors are used in steel beam–concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges ...
Sang-Hyo Kim, K S Kim, Oneil Han
exaly   +4 more sources

Experimental study on the bearing capacity of PZ shape composite dowel shear connectors with elliptical holes [PDF]

open access: yesScientific Reports, 2022
The push-out test was carried out in order to study the shear performance of perfobond ribs (PBL) and puzzle (PZ) shape composite dowel shear connectors which are used in corrugated steel–concrete composite bridge decks.
Pingming Huang   +4 more
doaj   +2 more sources

Shear Behavior of Superposed Perfobond Connectors Considering Lateral Constraints [PDF]

open access: yesApplied Sciences, 2022
Superposed perfobond connectors are a type of connector used in composite structures. When the construction conditions are limited to increase the diameter of the opening, the shear capacity of the connector can be improved by enhancing the confining ...
Jiangran Guo   +3 more
doaj   +2 more sources

Ensemble machine learning-based sensitivity and parametric assessment of headed stud shear connectors behavior in composite construction [PDF]

open access: yesScientific Reports
Indeed, understanding the behavior of headed stud shear connectors in composite steel and concrete construction is essential for ensuring structural integrity and optimal performance.
Ahed Habib   +6 more
doaj   +2 more sources

Experimental Research on the Shear Connectors in Foam Concrete with C-Channel Embedment [PDF]

open access: yesInternational Journal of Concrete Structures and Materials, 2018
In order to improve the longitudinal shear resistance between foam concrete and C-Channels, an investigation is carried out on the shear connectors in foam concrete with cold-formed steel double C-Channels embedment.
Dianzhong Liu, Fayu Wang, Feng Fu
doaj   +3 more sources

Home - About - Disclaimer - Privacy