Results 21 to 30 of about 586,736 (276)
Experimental assessment of ferritic stainless steel composite slabs [PDF]
This paper describes investigations into the structural behaviour of ferritic stainless steel floor decking in composite construction. Although commonly used in the automotive and industrial sectors, structural applications of ferritic stainless steels ...
Cashell, K
core +4 more sources
Shear connectors ensure effective interaction between wood beams and concrete slabs of composite beams, and their properties noticeably affect the fire resistance of timber-concrete composite beams.
Danrong Shi +3 more
doaj +2 more sources
The Shear Behavior of Insulated Precast Concrete Sandwich Panels Reinforced with BFRP
Typical insulated precast concrete sandwich panel (PCSP) systems are composed of two concrete wythes separated by a layer of insulation. The structural behavior of insulated PCSP systems heavily depends on elements between two wythes known as connectors,
Xia Liu, Xin Wang, Tan Yang, Zhishen Wu
doaj +1 more source
Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure. [PDF]
Shear connectors are used in steel beam–concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges ...
Kim SH, Kim KS, Lee DH, Park JS, Han O.
europepmc +2 more sources
A new design proposal for composite beams with powder actuated shear connectors [PDF]
This paper introduces a proposal for the SP 266.1325800 code update, which is applied as a national building code for composite structure design in Russian and some CIS countries.
Tonkikh Gennadiy, Chesnokov Denis
doaj +1 more source
Recent research on ductility of perforated shear connectors [PDF]
Significant implementation of Perfobond shear connectors in construction of composite steel-concrete structures resluted in development of entirely new type of shear connectors, denoted as perforated shear connectors.
Spremić, Milan +2 more
core +5 more sources
Experimental investigation on corroded stud connectors under strain rates effect
Shear connectors have been widely used in bridge and steel engineering to transfer the dynamic load effect between the neighbour elements. The shear connectors are exposed to moist air, and corrosion is unavoidable.
Huan-huan Du +3 more
doaj +1 more source
Effect of shear connector spacing and layout on the shear connector capacity in composite beams
A three dimensional nonlinear finite element model has been developed to study the behaviour of composite beams with profiled sheeting oriented perpendicular to its axis. The analysis of the push test was carried out using ABAQUS/Explicit with slow load application to ensure a quasi-static solution. Both material and geometric nonlinearities were taken
Qureshi, Jawed +2 more
openaire +2 more sources
Structural Performance of Shear Connectors
The top flange of steel composite bridge girders are furnished with a shear connector, which is a steel projection that facilitates the necessary shear transfer between the steel girder and concrete slab to permit composite action. Shear connectors are essential for building solid connection points that withstand shear loading. The shear connectors are
Thomson, Felix, Jikhil Joseph
openaire +2 more sources
Shear Behavior of Superposed Perfobond Connectors Considering Lateral Constraints
Superposed perfobond connectors are a type of connector used in composite structures. When the construction conditions are limited to increase the diameter of the opening, the shear capacity of the connector can be improved by enhancing the confining ...
Jiangran Guo +3 more
doaj +1 more source