Crestbond shear connector for load transfer on concrete filled composite columns in fire
: This paper presents a numerical study of the Crestbond shear connector, characterized by a steel plate with regular cuttings, when used as a load transfer element in concrete filled composite columns in fire.
Luiz Fernando Pereira do Prado +2 more
doaj +1 more source
Behaviour of Corroded Single Stud Shear Connectors [PDF]
In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested.
Wen Xue, Ju Chen, Ji-Hua Zhu
openaire +2 more sources
To investigate the behaviour of composite action with various shear connectors, push-out tests were performed for eight specimens. Test parameters includes are type of shear connector (headed stud connector and channel connector), number of connectors ...
P. SANGEETHA +2 more
doaj
Behaviour of Innovative Concrete Sandwich Panels with Pervious Concrete Core under Flexural Bending
Research studies investigating the possibility of using new core material (other than polystyrene) in concrete sandwich panels are being reported in the literature. In this paper, lightweight pervious concrete core is proposed as a new alternative.
Jeyabalan ARUNRAJ CHRISTADOSS +1 more
doaj +1 more source
An Energy Dissipating Seismic Connector for Precast Concrete Shear Walls
In this study, several steel connector shapes were analytically evaluated as potential new seismic energy dissipating devices between vertical precast concrete shear wall panels.
Mohammed Aljuboori, Habib Tabatabai
doaj +1 more source
Bolted shear connectors in steel–concrete composite structures: Shear behavior
The use of bolted shear connectors is of great importance to the sustainable development of steel–concrete composite structures. In this paper, an experimental program consisting of four push-out specimens is performed to investigate the effects of bolt length and fabrication method of concrete slabs on the shear behavior of single-nut embedded bolted ...
Xiaoyang Liu +9 more
openaire +2 more sources
Push-out Test of Profiled Metal Decking Slabs with Cold-formed Steel Beams and Rebar Shear Connector
New methods to provide shear strength on the cold-formed steel (CFS) lipped c-channel section composite beam encased with concrete partially is proposed using rebars embedded in concrete. The development of research on the CFS composite beams technology
Achmad Abraham S. ARMO +2 more
doaj +3 more sources
Experimental study on interfacial shear behavior of PBL shear connector deeply embedded in UHPC
To analyze the shear capacity and failure mechanism of perfobond strip (PBL) connectors in the junction of the steel-UHPC composite pedestrian truss bridge, this study conducted monotonic loading push-out tests on four specimens of PBL shear connector ...
Zhipeng Cao +5 more
doaj +1 more source
Parametric Push-Out Analysis on Perfobond Rib with Headed Stud Mixed Shear Connector
In steel and concrete composite structures, it is unfavourable to install many headed studs or perfobond ribs with narrow spacings at the joints. To solve this problem, a new type of a mixed shear connector was developed by combining a headed stud and ...
Shuangjie Zheng, Chen Zhao, Yangqing Liu
doaj +1 more source
Shear Behavior of FRP Connectors in Precast Sandwich Insulation Wall Panels
Glass fiber reinforced polymer (FRP) composite connectors used in precast sandwich insulation wall panels directly affect the safety of the wall.
Dong Chen +4 more
doaj +1 more source