Results 221 to 230 of about 8,202,745 (292)
Some of the next articles are maybe not open access.
Application of shunt active power filters in active distribution networks
2022 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe), 2022Constant increase of electricity demand and integrated renewable energy sources in the grid results in harmonic distortions which can impair power quality (PQ). This paper proposes a methodology for the selection of shunt active power filters as a possible solution to these problems and suggests a way to determine the reference current of the filter ...
Mario Primorac +3 more
openaire +3 more sources
Harmonic Reduction Strategies for EV Charging in Power Systems Using Shunt Active Power Filter
2023 3rd International Conference on Emerging Frontiers in Electrical and Electronic Technologies (ICEFEET), 2023The widespread adoption of electric vehicles (EVs) globally and the large-scale integration of EV chargers into the distribution grid have led to significant concerns about the quality of power and current in the system.
Nishant Chaudhary +5 more
semanticscholar +1 more source
Grid Harmonic Current Correction Based on Parallel Three-Phase Shunt Active Power Filter
IEEE transactions on power electronics, 2022This article presents a finite-set model predictive control (FS-MPC) applied to the shunt active power filters (SAPF) based on three-phase inverters connected in parallel sharing the same dc-link.
Laysa L. de Souza +4 more
semanticscholar +1 more source
A Bi-Sliding Mode PI Control of DC-Link Voltage of Three-Phase Three-Wire Shunt Active Power Filter
IEEE Journal of Emerging and Selected Topics in Power Electronics, 2022A novel bi-sliding mode PI control (bi-SMPIC) of the dc-link voltage of a three-phase three-wire shunt active power filter (APF) is proposed in this article.
Zi-Cheng Li +4 more
semanticscholar +1 more source
Direct power control of shunt active filter
2007 European Conference on Power Electronics and Applications, 2007This paper presents a new control method entitled direct power control (DPC) for shunt active power filtering, which is applied to eliminate line current harmonics and compensate reactive power. Its main goal is to rebuild active and reactive powers to be compared to references values using hysteresis control.
Chaoui, Abdelmadjid +3 more
openaire +2 more sources
Shunt active power filter with ADMC330
Proceedings IPEMC 2000. Third International Power Electronics and Motion Control Conference (IEEE Cat. No.00EX435), 2002In this paper, we describe a scheme for the shunt active power filter with ADMC330 (single chip DSP microcontroller) which was developed successfully. The results of experiment indicate that harmonic currents in three-phase three-wire system could be compensated successfully.
null Junfei Hu +2 more
openaire +1 more source
Adaptive Compensation of Reactive Power with Shunt Active Power Filters
Conference Record of the 2006 IEEE Industry Applications Conference Forty-First IAS Annual Meeting, 2006This paper describes an adaptive method for compensating the reactive power with an active power filter (APF), which is initially rated for mitigation of only the harmonic currents given by a nonlinear industrial load. It is proven that, if the harmonic currents do not load the APF at the rated power, the available power can be used to provide a part ...
Asiminoaei, Lucian +3 more
openaire +3 more sources
2013
Shunt active power filters have been introduced as a way to overcome the power quality problems caused by nonlinear and reactive loads [9, 14, 23]. These power electronics devices are designed with the goal of obtaining a power factor close to 1 and achieving current harmonics and reactive power compensation [5, 6, 15]. The usual approaches [5, 15] for
Germán A. Ramos +2 more
openaire +1 more source
Shunt active power filters have been introduced as a way to overcome the power quality problems caused by nonlinear and reactive loads [9, 14, 23]. These power electronics devices are designed with the goal of obtaining a power factor close to 1 and achieving current harmonics and reactive power compensation [5, 6, 15]. The usual approaches [5, 15] for
Germán A. Ramos +2 more
openaire +1 more source
, 2021
This paper investigates the problem of controlling a single phase shunt active power filter (SAPF) connected to two photovoltaic arrays through a half bridge inverter involving two DC link capacitors.
Zineb Hekss +5 more
semanticscholar +1 more source
This paper investigates the problem of controlling a single phase shunt active power filter (SAPF) connected to two photovoltaic arrays through a half bridge inverter involving two DC link capacitors.
Zineb Hekss +5 more
semanticscholar +1 more source
A Sliding Mode SVPWM Method for a HTS Shunt Active Power Filter
IEEE transactions on applied superconductivity, 2021A sliding mode controller based on SVPWM strategy (SMC-SVPWM) is proposed for three-phase voltage-source-converter-based shunt active power filter. Superconducting magnetic energy storage is used to improve the filtering performance.
Youjin Li +5 more