Results 221 to 230 of about 5,603 (270)
Some of the next articles are maybe not open access.
2013
Shunt active power filters have been introduced as a way to overcome the power quality problems caused by nonlinear and reactive loads [9, 14, 23]. These power electronics devices are designed with the goal of obtaining a power factor close to 1 and achieving current harmonics and reactive power compensation [5, 6, 15]. The usual approaches [5, 15] for
Germán A. Ramos +2 more
openaire +1 more source
Shunt active power filters have been introduced as a way to overcome the power quality problems caused by nonlinear and reactive loads [9, 14, 23]. These power electronics devices are designed with the goal of obtaining a power factor close to 1 and achieving current harmonics and reactive power compensation [5, 6, 15]. The usual approaches [5, 15] for
Germán A. Ramos +2 more
openaire +1 more source
Design of an asymmetric multilevel shunt active power filter
2015 IEEE 24th International Symposium on Industrial Electronics (ISIE), 2015Design criteria are addressed to select the parameters of an asymmetric multilevel shunt active power filter based on a Cascaded H-Bridge topology. The proposed approach is meant to simultaneously compensate both fundamental reactive power and current harmonics.
Javier Muñoz 0001 +5 more
openaire +1 more source
A predictive deadbeat control in shunt active power filter
2011 International Conference on Wireless Communications and Signal Processing (WCSP), 2011Successive improvement of microprocessor performance makes the deadbeat control applied more widely in active power filter. However, the deadbeat control is susceptible to the noise when it is used to deal with the instantaneous current sampling data. This paper proposed a predictive deadbeat control method based on coherent average.
Zhihua Bao, Zongchen Wang, Shibing Zhang
openaire +1 more source
On the design of shunt active filter for improving power quality
2008 IEEE International Symposium on Industrial Electronics, 2008Several schemes and control techniques have been proposed in active power filtering these last years, often assuming that all the components are well sized, or at least they do not affect the control algorithm performance. The first step in designing an active filter is to select suitable values.
Chaoui, Abdelmadjid +3 more
openaire +1 more source
A shunt active power filter control for unbalanced conditions
10th IEEE International Conference on Electronics, Circuits and Systems, 2003. ICECS 2003. Proceedings of the 2003, 2004This paper first presents a simple control technique for active filters to compensate current harmonics and reactive power of nonlinear loads. This method is usable for both single-phase and three-phase systems. Then a new method for load balancing and reactive power compensation for unbalanced sinusoidal load currents is presented.
Seyed Hossein Hosseini 0002 +2 more
openaire +1 more source
A Matlab-Simulink Approach To Shunt Active Power Filters
ECMS 2011 Proceedings edited by: T. Burczynski, J. Kolodziej, A. Byrski, M. Carvalho, 2011Due to the wide spread of power electronics equipment in modern electrical systems, the increase of the harmonics disturbance in the ac mains currents has became a major concern due to the adverse effects on all equipment. This paper presents the analysis and simulation using Matlab Simulink of a three-phase four wire neutral clamped active power ...
George Adam +2 more
openaire +1 more source
Apparent power ratio of the Shunt Active Power Filter
2008 13th International Power Electronics and Motion Control Conference, 2008The main purpose of this paper is the evaluation of the shunt active power filter apparent power ratio between the apparent power generated by the source power system to the load and the compensation apparent power produced by the shunt APF to force the currents circulating toward the source to be sinusoidal and balanced. This ratio allows defining the
A. Kouzou +4 more
openaire +1 more source
Simulation and comparison between hybrid active power filter and shunt active power filter
2015 International Conference on Electrical, Electronics, Signals, Communication and Optimization (EESCO), 2015The shunt active power filters (SAPFs) and hybrid active power filter (HAPF) is used for practical solution to solve the electric power quality, (EPQ) issues. The emerging power-electronic devices and the new developments in digital signal processing (DSP), have made possible its practical use. The active power filters can compensate the nonlinear load
D.R. Dobariya, P.A. Upadhyay
openaire +1 more source
Improved shunt active power filters
2008 International School on Nonsinusoidal Currents and Compensation, 2008This paper describes a shunt active power filters (APF) with improved dynamic performance. When the value of load current changes rapidly, the APF transient response is too slow, the line current suffers from dynamic distortion. This distortion causes an increase of harmonic content in the line current, which is dependent on a time constant.
openaire +1 more source
Energy controlled shunt active power filters [PDF]
PurposeShunt active power filters are used to decrease or almost eliminate non‐active currents flowing through the supply source. Numerous control methods of active filters have been proposed in many papers. The aim of this paper is to demonstrate a simple but very effective method of obtaining the compensated load active current.Design/methodology ...
openaire +1 more source

