Results 41 to 50 of about 61,877 (349)

System configuration, fault detection, location, isolation and restoration: a review on LVDC Microgrid protections [PDF]

open access: yes, 2019
Low voltage direct current (LVDC) distribution has gained the significant interest of research due to the advancements in power conversion technologies. However, the use of converters has given rise to several technical issues regarding their protections
Bououden   +11 more
core   +1 more source

Assessment of unintentional islanding operations in distribution networks with large induction motors [PDF]

open access: yes, 2020
This paper is aimed at assessing the impact of unintentional islanding operations (IOs) in the presence of large induction motors (IMs) within distribution networks (DNs).
Bosch Tous, Ricardo   +3 more
core   +2 more sources

Research on Single-Phase Grounding Fault Line Selection in Resonant Grounding System Based on Median Complementary Ensemble Empirical Mode Decomposition and Multiscale Permutation Entropy Normalization and K-Means Algorithm

open access: yesProcesses
When a single-phase grounding fault occurs in a resonant grounding system, due to the compensation effect of the arc coil on the system, there are problems such as the fault signal amplitude and the signal waveform being close, which leads to ...
Yueheng Li, Chen Li, W. Cao
semanticscholar   +1 more source

A novel traveling-wave-based method improved by unsupervised learning for fault location of power cables via sheath current monitoring [PDF]

open access: yes, 2019
In order to improve the practice in maintenance of power cables, this paper proposes a novel traveling-wave-based fault location method improved by unsupervised learning.
Li, Mingzhen   +4 more
core   +1 more source

A novel single‐phase grounding fault voltage full compensation topology based on antiphase transformer

open access: yesIET Generation, Transmission & Distribution, 2021
Multi-tap and multi-capacitors type arc suppression coils are commonly used in distribution systems. Due to their low compensation accuracy and limited arc suppression capability, it is hardly to avoid personal safety accidents and wildfires absolutely ...
Xiaobin Cai   +5 more
semanticscholar   +1 more source

Analysis of single phase ground fault characteristics of low resistance ground active distribution network

open access: yesJournal of Physics: Conference Series, 2021
Abstract A large number of distributed generators access to low resistance grounding system may have great influence on the fault characteristics of single phase ground. In view of low resistance ground active distribution network, the connection mode of Inverter-interfaced Distributed Generators (IIDG) is discussed comprehensively based
Na Wu   +5 more
openaire   +1 more source

Faulty Section Location Method Based on Dynamic Time Warping Distance in a Resonant Grounding System

open access: yesEnergies, 2022
When a single-phase grounding fault occurs in a resonant grounding system, the determination of the fault location remains a significant challenge due to the small fault current and the instability of the grounding arc.
Yu He   +6 more
doaj   +1 more source

Research of Single-phase Grounding Fault Simulation for Small Current Grounding System

open access: yesDEStech Transactions on Environment, Energy and Earth Sciences, 2017
Our country generally uses small current grounding system (the neutral point no direct grounding system). Due to the fault current is too small to identify. So the distribution network operators have been plagued by this kind of fault line selection accuracy. This research establishes simulink model to analyze the fault of single-phase grounding system
Wei-wei GE   +4 more
openaire   +2 more sources

The Quantum Socket: Three-Dimensional Wiring for Extensible Quantum Computing [PDF]

open access: yes, 2016
Quantum computing architectures are on the verge of scalability, a key requirement for the implementation of a universal quantum computer. The next stage in this quest is the realization of quantum error correction codes, which will mitigate the impact ...
Bateman, J. D.   +13 more
core   +2 more sources

Single-phase Grounding Fault Location Technology Based on Edge Calculation of Fault Components of the Positive-sequence Current

open access: yesJournal of Physics: Conference Series, 2022
In the one-phase-to-ground fault of the distribution network, due to the difference in the distribution of the positive sequence current constituents of each line, the information contained in the fault path and the non-fault path also has a certain ...
Zhenwei E   +6 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy