Results 41 to 50 of about 61,877 (349)
System configuration, fault detection, location, isolation and restoration: a review on LVDC Microgrid protections [PDF]
Low voltage direct current (LVDC) distribution has gained the significant interest of research due to the advancements in power conversion technologies. However, the use of converters has given rise to several technical issues regarding their protections
Bououden +11 more
core +1 more source
Assessment of unintentional islanding operations in distribution networks with large induction motors [PDF]
This paper is aimed at assessing the impact of unintentional islanding operations (IOs) in the presence of large induction motors (IMs) within distribution networks (DNs).
Bosch Tous, Ricardo +3 more
core +2 more sources
When a single-phase grounding fault occurs in a resonant grounding system, due to the compensation effect of the arc coil on the system, there are problems such as the fault signal amplitude and the signal waveform being close, which leads to ...
Yueheng Li, Chen Li, W. Cao
semanticscholar +1 more source
A novel traveling-wave-based method improved by unsupervised learning for fault location of power cables via sheath current monitoring [PDF]
In order to improve the practice in maintenance of power cables, this paper proposes a novel traveling-wave-based fault location method improved by unsupervised learning.
Li, Mingzhen +4 more
core +1 more source
Multi-tap and multi-capacitors type arc suppression coils are commonly used in distribution systems. Due to their low compensation accuracy and limited arc suppression capability, it is hardly to avoid personal safety accidents and wildfires absolutely ...
Xiaobin Cai +5 more
semanticscholar +1 more source
Abstract A large number of distributed generators access to low resistance grounding system may have great influence on the fault characteristics of single phase ground. In view of low resistance ground active distribution network, the connection mode of Inverter-interfaced Distributed Generators (IIDG) is discussed comprehensively based
Na Wu +5 more
openaire +1 more source
Faulty Section Location Method Based on Dynamic Time Warping Distance in a Resonant Grounding System
When a single-phase grounding fault occurs in a resonant grounding system, the determination of the fault location remains a significant challenge due to the small fault current and the instability of the grounding arc.
Yu He +6 more
doaj +1 more source
Research of Single-phase Grounding Fault Simulation for Small Current Grounding System
Our country generally uses small current grounding system (the neutral point no direct grounding system). Due to the fault current is too small to identify. So the distribution network operators have been plagued by this kind of fault line selection accuracy. This research establishes simulink model to analyze the fault of single-phase grounding system
Wei-wei GE +4 more
openaire +2 more sources
The Quantum Socket: Three-Dimensional Wiring for Extensible Quantum Computing [PDF]
Quantum computing architectures are on the verge of scalability, a key requirement for the implementation of a universal quantum computer. The next stage in this quest is the realization of quantum error correction codes, which will mitigate the impact ...
Bateman, J. D. +13 more
core +2 more sources
In the one-phase-to-ground fault of the distribution network, due to the difference in the distribution of the positive sequence current constituents of each line, the information contained in the fault path and the non-fault path also has a certain ...
Zhenwei E +6 more
semanticscholar +1 more source