Size-exclusion chromatography-based enrichment of extracellular vesicles from urine samples [PDF]
Renal biopsy is the gold-standard procedure to diagnose most of renal pathologies. However, this invasive method is of limited repeatability and often describes an irreversible renal damage.
Inés Lozano-Ramos +7 more
doaj +3 more sources
Enrichment of extracellular vesicles from human synovial fluid using size exclusion chromatography
As a complex biological fluid, human synovial fluid (SF) presents challenges for extracellular vesicle (EV) enrichment using standard methods. In this study of human SF, a size exclusion chromatography (SEC)-based method of EV enrichment is shown to ...
Andrew D. Foers +8 more
doaj +2 more sources
Partial Purification of Peroxiredoxin-2 From Porcine Skeletal Muscle
Fresh meat quality is adversely affected by protein oxidation. However, a fundamental understanding of the diverse factors that influence protein oxidation in postmortem muscle remains elusive.
Edward M;. Steadham +3 more
doaj +2 more sources
Characterization of hemodialysis membranes by inverse size exclusion chromatography [PDF]
Inverse size exclusion chromatography (i-SEC) was used to characterize three different cellulosic hollow fiber hemodialysis membranes, i.e. low-flux cuprophan and hemophan and high-flux RC-HP400A.
Bargeman, Derk +5 more
core +3 more sources
Size-exclusion chromatographic NMR of polymer mixtures [PDF]
The use of chromatographic stationary phases or solvent modifiers to modulate diffusion properties in NMR experiments is now well established. Their use can be to improve resolution in the diffusion domain or to provide an insight into analyte–modifier ...
Adams +32 more
core +1 more source
Purification of bacteriocins using size-exclusion chromatography
The bacteriocin purification involves following main steps. a). Extraction of cell-free-supernatant of bacteria. b). Ammonium sulfate precipitation. c). Dialysis. d). Diafiltration using PVP and e). Size-exclusion chromatography.
Vivek K. Bajpai +2 more
doaj +1 more source
Calibration of ultrafiltration membranes against size exclusion chromatography columns [PDF]
Using the extension of the concept of universal calibration parameter, yielding a relation between the hydrodynamic volume of molecules and the elution volume in sizeexclusionchromatography (SEC), to retention coefficients in ultrafiltration (UF), we ...
Aimar, Pierre, Meireles, Martine
core +2 more sources
Size exclusion chromatography for extraction of serum bile acids.
A major problem in the measurement of serum bile acids is their quantitative extraction from the high molecular protein matrix. In our hands, the standard techniques of adsorption and reversed-phase chromatography have yielded incomplete recovery for ...
R Nuber, H Maucher, EF Stange
doaj +1 more source
Size exclusion chromatography as green support for forced degradation study of adalimumab
Size exclusion chromatography (SEC) has become a powerful tool for analysing size variants of biologic drugs in their native form. Modern SEC can be defined by the use of chromatographic columns packed with sub-3 µm particles, allowing an increase in ...
Kovačić Jelena +3 more
doaj +1 more source
Uncertainty of Size-Exclusion Chromatography Method in Quality Control of Bevacizumab Batches
In addition to the analytical challenges related to the size and complexity of biopharmaceutical drugs, the inherent variability that arises due to their manufacturing process requires monitoring throughout the production process to ensure the safety and
Alexis Oliva, Matías Llabrés
doaj +1 more source

