Results 161 to 170 of about 4,329,351 (193)
Some of the next articles are maybe not open access.
Frequency-Doubling Perimetry: Comparison With Standard Automated Perimetry to Detect Glaucoma
American Journal of Ophthalmology, 2007To compare second generation frequency-doubling perimetry (FDP) with standard automated perimetry (SAP) to detect glaucomatous visual field abnormalities.Prospective, cross-sectional, controlled observational study.Fifty eyes of 50 patients with glaucoma with confirmed SAP visual field abnormalities and 42 eyes from 42 normal control subjects were ...
Narakorn, Leeprechanon +4 more
openaire +2 more sources
Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma
Standard automated perimetry (SAP) is today still the clinical standard for the management of glaucoma and its progression, though it has been shown that it may detect the disease only after the death of a high number of retinal ganglion cells (RGCs).
Paolo Fogagnolo +2 more
exaly +2 more sources
2016
This chapter aims to describe and update several aspects on visual field testing in glaucoma, including its fundaments, methodology, and illustrations. First, basic aspects on the visual field and standard automated perimetry are considered. Next, the importance of quality of results for both single field analysis and visual field series is emphasized ...
Francisco Javier Goñi, Krapez Maja
openaire +1 more source
This chapter aims to describe and update several aspects on visual field testing in glaucoma, including its fundaments, methodology, and illustrations. First, basic aspects on the visual field and standard automated perimetry are considered. Next, the importance of quality of results for both single field analysis and visual field series is emphasized ...
Francisco Javier Goñi, Krapez Maja
openaire +1 more source
Relationship between flicker FDF perimetry and standard automated perimetry
Acta Ophthalmologica, 2010Abstract Purpose To compare the main indices of flicker FDF perimetry (FDF, Heidelberg Engineering, Germany) with standard automated perimetry (SAP). Methods Twenty healthy subjects and twenty‐three glaucoma patients were prospectively and consecutively selected.
P CALVO PEREZ +7 more
openaire +1 more source
Feasibility and outcome of automated kinetic perimetry in children
Visual field testing in children is often performed using a Goldmann perimeter. Because the technique is performed manually, it is difficult to standardize, and stimuli are often presented too quickly.
Bettina Kathrin Wabbels, Birgit Lorenz
exaly +2 more sources
Repeatability of Online Circular Contrast Perimetry Compared to Standard Automated Perimetry
Journal of GlaucomaPrécis: Online circular contrast perimetry provides visual field assessment on any computer or tablet with no extra hardware. It has good test repeatability and reliability that is comparable with standard automated perimetry.
Joshua, Meyerov +4 more
openaire +2 more sources
Archives of Ophthalmology, 2000
To compare progression in short-wavelength automated perimetry (SWAP) and white-on-white (standard) perimetry in eyes with progressive glaucomatous changes of the optic disc detected by serial stereophotographs.Forty-seven glaucoma patients with at least 2 disc stereophotographs more than 2 years apart, along with standard perimetry and SWAP ...
C A, Girkin +6 more
openaire +2 more sources
To compare progression in short-wavelength automated perimetry (SWAP) and white-on-white (standard) perimetry in eyes with progressive glaucomatous changes of the optic disc detected by serial stereophotographs.Forty-seven glaucoma patients with at least 2 disc stereophotographs more than 2 years apart, along with standard perimetry and SWAP ...
C A, Girkin +6 more
openaire +2 more sources
Relationship between flicker FDF perimetry and standard automated perimetry in glaucoma patients
Acta Ophthalmologica, 2010Abstract Purpose To compare the main indices of flicker FDF perimetry (FDF, Heidelberg Engineering, Germany) with standard automated perimetry (SAP) in glaucoma patients. Methods Twenty‐three open‐angle glaucoma patients were prospectively and consecutively selected. Glaucomatous patients had an intraocular pressure higher than 21 mmHg and glaucomatous
P CALVO PEREZ +7 more
openaire +1 more source
Standard automated perimetry for glaucoma and diseases of the retina and visual pathways: current and future ...
Lisa Nivison-Smith +2 more
exaly +1 more source
Journal of Glaucoma, 2020
Précis: This eye movement perimetry (EMP) study describes the development of saccadic reaction time (SRT)-based visual field plots, which could effectively display the presence, location, and extent of glaucomatous defects and support clinical decision-making.
Mazumdar, Deepmala +6 more
openaire +3 more sources
Précis: This eye movement perimetry (EMP) study describes the development of saccadic reaction time (SRT)-based visual field plots, which could effectively display the presence, location, and extent of glaucomatous defects and support clinical decision-making.
Mazumdar, Deepmala +6 more
openaire +3 more sources

