Results 1 to 10 of about 7,950 (309)
General-compensation-purpose Static var Compensator prototype
Static var Compensator (SVC) has a general topology and its operational principle allows its application with distinct compensation purposes, such as voltage regulation or load balancing.
Hildo Guillardi, Júnior +3 more
doaj +4 more sources
MATLAB Simulation Research on Static Var Compensator [PDF]
TCR-TSC static reactive power compensator (SVC) is the most widely used in the field of power system reactive power compensation. This type of reactive power compensator can not only compensate the reactive power required in the power system, but also ...
Chen JinBo, Hu WenYu
doaj +2 more sources
Analysis of the combined effects of SVC and SSSC controllers to improve power system stability
The primary challenge facing the electricity transmission system in the aftermath of the disruption is reestablishing stability. Through adjustment of the transmission parameters, the Flexible AC Transmission System (FACTS) devices have the potential to ...
Suraj Ankush Dahat, Ashwin Dhabale
doaj +1 more source
This paper discussed about the influence of Static VAR Compensator (SVC) in transmission system 150 kV, Sumbagut region. Transmission system and SVC parameters in this study is simulated by using computer.
Syiska Yana +2 more
doaj +3 more sources
Software Tool for Optimal Placement and Sizing of Shunt Var Compensators in Power Systems
This paper presents a MATLAB-based power system software tool, named as OPSVC for optimal placement and sizing of shunt Var compensators in both distribution and transmission systems. The OPSVC software incorporates the developed optimization algorithms
Reza Sirjani
doaj +2 more sources
Power analysis of static VAr compensators [PDF]
Analysis of three-phase loads usually assume them to be three impedances in a star or triangle connection. This is the reason why obtained results can only be considered valid for passive loads, strictly speaking. Analysis leading to the proposal of some static compensators is usually performed in this way, which induces to believe that this ...
Redondo Quintela, Félix +2 more
openaire +2 more sources
Harmonics Distribution in Electrical Power System Containing Static Var Compensator [PDF]
This research presents a harmonic analysis of the power system with static VARcompensator. The model is formed by parallel combination of Thyristor ControlReactor (TCR) with a bank of capacitor .This model based on use of harmonicswitching functions and ...
Mohammed K. Edan
doaj +1 more source
Analysis of Core Losses in Transformer Working at Static Var Compensator
This article presents the comparison of 3D and 2D finite element models of a power transformer designed for reactive power compensation stations. There is a lack of studies in the literature on internal electromagnetic phenomena in the active part of a ...
Piotr Osinski, Pawel Witczak
doaj +1 more source
Optimal location of static var compensator device for damping oscillations [PDF]
Problem statement: Static Var Compensators (SVC) devices are used to improve voltage and reactive power conditions in AC systems. An additional task of SVC is to increase transmission capacity as result of power oscillation damping.
Magaji, Nuraddeen, Mustafa, Mohd. Wazir
core +2 more sources
Comparison of SVC and TCSC installation in transmission line with loss minimization and cost of installation via particle swarm optimization [PDF]
The paper presents a comparison of performance Static Var Compensator (SVC) and Thyristor Controlled Series Compensator (TCSC) with objective function to minimize the transmission loss, improve the voltage and monitoring the cost of installation ...
Jumaat, Siti Amely, Musirin, Ismail
core +1 more source