Results 271 to 280 of about 583,507 (329)
Some of the next articles are maybe not open access.
IEEE transactions on dielectrics and electrical insulation, 2020
In an HVDC gas-insulated system, the surface of the insulator accumulates electric charges that distort the surface electric field and reduce the flashover voltage.
Tianyu Wang +4 more
semanticscholar +1 more source
In an HVDC gas-insulated system, the surface of the insulator accumulates electric charges that distort the surface electric field and reduce the flashover voltage.
Tianyu Wang +4 more
semanticscholar +1 more source
Nanotechnology, 2020
In high-voltage direct current (HVDC) transmission systems, electric charge accumulates on insulator surfaces, causing surface electric field distortion and flashover voltage reduction.
Tianyu Wang +4 more
semanticscholar +1 more source
In high-voltage direct current (HVDC) transmission systems, electric charge accumulates on insulator surfaces, causing surface electric field distortion and flashover voltage reduction.
Tianyu Wang +4 more
semanticscholar +1 more source
IEEE Transactions on Dielectrics and Electrical Insulation, 2018
Surface charge accumulation on the insulator surface and the resulting flashover voltage reduction are considered the primary factors to hinder the large-scale use of HVDC system, especially the gas-insulated system.
Boya Zhang +2 more
exaly +2 more sources
Surface charge accumulation on the insulator surface and the resulting flashover voltage reduction are considered the primary factors to hinder the large-scale use of HVDC system, especially the gas-insulated system.
Boya Zhang +2 more
exaly +2 more sources
Journal of Physics D: Applied Physics, 2020
In order to suppress surface charge accumulation, a nano-SiC/epoxy composite with nonlinear conduction characteristic was employed to coat a pure epoxy substrate in this paper.
Zijun Pan +5 more
semanticscholar +1 more source
In order to suppress surface charge accumulation, a nano-SiC/epoxy composite with nonlinear conduction characteristic was employed to coat a pure epoxy substrate in this paper.
Zijun Pan +5 more
semanticscholar +1 more source
Nanotechnology, 2020
In high-voltage direct current transmission systems, charges accumulate at the gas—solid interface, distorting the local field strength, causing a reduction in the flashover voltage, and threatening the safe and reliable operation of the power system ...
Tian-Yu Wang +4 more
semanticscholar +1 more source
In high-voltage direct current transmission systems, charges accumulate at the gas—solid interface, distorting the local field strength, causing a reduction in the flashover voltage, and threatening the safe and reliable operation of the power system ...
Tian-Yu Wang +4 more
semanticscholar +1 more source
Surface Charge Accumulation of Zoning-Coating GIS Insulator in Different Gas Atmospheres
IEEE Transactions on Plasma ScienceZoning-coating that deposits various functional coating materials on different surface regions of insulators installed in gas-insulated switchgear (GIS) has been recognized as a promising method to suppress surface charge accumulation.
Yu Gao +5 more
semanticscholar +1 more source
Preclinical studies have demonstrated that nanoparticles (NPs) hold significant potential for advancing cancer therapy by enhancing therapeutic efficacy while reducing side effects.
Indra Van Zundert +2 more
exaly +2 more sources
Characteristics of Surface Charge Accumulation on Spacers and Its Influencing Factors
Charge accumulation usually happens on the surface of spacers under DC operation, which is susceptible to inducing surface flashover. In order to explore the surface charge accumulation mechanisms and the influences of dielectric conductivity, gas ion ...
Hui Jiang, Yufei Han
exaly +2 more sources
International Journal of Electrical Power & Energy Systems, 2019
Under AC, DC and switching impulse voltages, the surface charges accumulated on the basin insulators of Gas Insulated Substation (GIS) or Gas Insulated Metal Enclosed Transmission Line (GIL) could distort local electric field and even reduce the surface ...
B. Qi, C. Gao, Chengrong Li, Jun Xiong
semanticscholar +1 more source
Under AC, DC and switching impulse voltages, the surface charges accumulated on the basin insulators of Gas Insulated Substation (GIS) or Gas Insulated Metal Enclosed Transmission Line (GIL) could distort local electric field and even reduce the surface ...
B. Qi, C. Gao, Chengrong Li, Jun Xiong
semanticscholar +1 more source

