Switched reluctance generators for wind energy applications

Proceedings of PESC '95 - Power Electronics Specialist Conference, 2002
The switched reluctance machine has very good characteristics in term of efficiency, control simplicity and robustness. The rotor is made of solid iron with no electrical excitation and this results in considerable robustness and reliability. The machine is cost competitive with the cage induction motor, has superior efficiency to it and its power ...
R. Cardenas, W.F. Ray, G.M. Asher
openaire   +1 more source

On the suitability of switched reluctance drives for starter/generator application

Vehicular Technology Conference. IEEE 55th Vehicular Technology Conference. VTC Spring 2002 (Cat. No.02CH37367), 2003
This paper addresses various aspects of the switched reluctance (SR) machine based starter/alternator (S/A) system for a more electric car. Inherent simplicity of the machine geometry and control, offering high efficiency and a very long constant power speed ratio along with a rugged structure and safe operation are among the most salient attributes of
openaire   +1 more source

A voltage control strategy for Switched Reluctance Generator

2013 International Electric Machines & Drives Conference, 2013
This paper presents a strategy to control the terminal voltage of a Switched Reluctance Generator. It is implemented using a closed loop feedback that senses the shunt capacitor smoothed generated voltage at the generator terminals. The voltage error feeds a PI controller that in turn governs the switches of the electronic converter used to drive the ...
G.P. Viajante   +5 more
openaire   +1 more source

Sensorless Switched Reluctance Starter/Generator Performance

IEEE Industry Applications Magazine, 1997
This article compares the performance of a high speed switched reluctance starter/generator (SR S/G) system when operating with a resolver to that when operating resolverless, or sensorless. The SR SIG system is a 270 Vdc system that performs two primary functions.
Stephen R. Jones, Barry T. Drager
openaire   +1 more source

Switched Reluctance Generator Control for Optimal Power Generation With Current Regulation

IEEE Transactions on Industry Applications, 2012
The paper presents a novel method of controlling switched reluctance generators (SRGs) for maximum efficiency with active current regulation. The effect of varying the input control parameters on the efficiency of the SRG is first analyzed through exhaustive data collection through simulation and experiments.
Chandan Sikder   +2 more
openaire   +1 more source

Switched Reluctance Generator : An Alternative Source for Microgrid

2023 15th International Conference on Software, Knowledge, Information Management and Applications (SKIMA), 2023
Slamet Riyadi   +4 more
openaire   +1 more source

Magnetic Field Analysis and Structural Optimization of Deflection Double Stator Switched Reluctance Generator

Lecture Notes in Electrical Engineering, 2021
Qunjing Wang, Yu Xuze, Wang Qunjing
exaly  

Switched Reluctance Machines as Three-Phase AC Autonomous Generator

IEEE Transactions on Magnetics, 2006
R Rabinovici