Results 81 to 90 of about 10,256 (232)
Active distribution power system with multi-terminal DC links [PDF]
A fast power restoration operational scheme and relevant stabilizing control is proposed for active distribution power systems with multi-terminal DC network in replacement of the conventional normal open switches. A 9-feeder benchmark distribution power
Chen, Dong, Xu, Lie, Zhang, Wendian
core +2 more sources
Design Method for Improving Power Quality in Urban Public Spaces Using Wind Energy
“This study presents a novel method to enhance power quality in urban public spaces by integrating vertical‐axis wind turbines with a UPQC system, achieving up to 75% reduction in voltage sags and 65% in swells, while promoting sustainable, renewable energy use.” ABSTRACT In urban public spaces, maintaining high power quality is very much needed for ...
Zexin Wu
wiley +1 more source
The switching action of the main circuit breaker of the train will produce switching overvoltage. In order to suppress the switching overvoltage, the phase selection control of the circuit breaker is required.
Ruoyu Li +3 more
doaj +1 more source
This article proposes an integrated design method for a 12 kV intelligent ring main unit and constructs a fault diagnosis and isolation model. Firstly, building an integrated hardware platform can significantly improve perception speed and fusion potential.
Rongrong Shan, Jieyun Qiu, Dong Han
wiley +1 more source
This study establishes a hybrid microgrid model integrating a Doubly Fed Induction Generator (DFIG), a photovoltaic (PV) array, and a battery energy storage system, and proposes a coordinated control framework. The DFIG regulates DC‐bus voltage through the grid‐side converter and performs maximum power tracking via the rotor‐side converter, while the ...
Chunyan Li +4 more
wiley +1 more source
International White Book on DER Protection : Review and Testing Procedures [PDF]
This white book provides an insight into the issues surrounding the impact of increasing levels of DER on the generator and network protection and the resulting necessary improvements in protection testing practices.
Abdulhadi, Ibrahim Faiek +7 more
core
Commutation failure caused by AC filter switching In HVDC system
Switching AC filter may cause harmonic impact, which may lead to commutation failure of HVDC system. Here, the commutation failure mechanism of HVDC system caused by AC filter switching is studied.
Meng Liu +3 more
doaj +1 more source
Inverter-converter automatic paralleling and protection [PDF]
Electric control and protection circuits for parallel operation of inverter ...
Doughman, C. L. +2 more
core +1 more source
Behavioral models of digital IC ports from measured transient waveforms [PDF]
This paper addresses the behavioral modeling of output ports of digital integrated circuits via the identification of nonlinear parametric models.
Maio, Ivano Adolfo +1 more
core +1 more source
Industrial Fieldbus Improvements in Power Distribution and Conducted Noise Immunity With No Extra Costs [PDF]
Industrial distributed control continues the move toward networks at all levels. At lower levels, control networks provide flexibility, reliability, and low cost, although perhaps the simplest but most important advantage is the reduced volume of ...
Barbancho Concejero, Antonio +3 more
core +1 more source