Results 11 to 20 of about 84,850 (291)
Release of silicone oil droplets from syringes
Background Intravitreal silicone oil droplets have been found in the vitreous. The aim of this study is to compare the rates of silicone oil released by different brands of commonly used syringes for intravitreal injection after agitation by flicking ...
Gustavo Barreto Melo +8 more
doaj +2 more sources
Introducing auto-disable syringes to the national immunization programme in Madagascar
OBJECTIVE: To evaluate the safety and coverage benefits of auto-disable (AD) syringes, weighed against the financial and logis- tical costs, and to create appropriate health policies in Madagascar.
Paul K. Drain +3 more
doaj +2 more sources
Introducing auto-disable syringes to the national immunization programme in Madagascar
OBJECTIVE: To evaluate the safety and coverage benefits of auto-disable (AD) syringes, weighed against the financial and logis- tical costs, and to create appropriate health policies in Madagascar.
Drain Paul K. +3 more
doaj +1 more source
Hot-melt Extrusion Through Syringes [PDF]
The use of solid dispersions to formulate poorly water soluble drugs is a growing field in the pharmaceutical sciences. Hot-melt extrusion is a common method for producing dispersions.
O'Connell, Sean Patrick
core +5 more sources
Class of 2023 Abstract and PosterSpecific Aims: To evaluate the accuracy and reproducibility of small-volume injections from prefilled syringes and different sizes of polypropylene syringes.
Kim, Yoona
core +5 more sources
Heparin release kinetics in blood gas syringes [PDF]
Background: In view of the urgency of results quality and operational availability of point of care analyzers is of high importance in ICUs and operational theatres. Methods: We investigated the influence of time on release and total amount of Heparin in
Bechmann, Volker +2 more
core +1 more source
Injecting behaviour and service use among young injectors in Albania, Moldova, Romania and Serbia. [PDF]
BACKGROUND: This study examines socio-demographic profiles, injecting risk and use of health services among young injectors (15-24) in Albania, Moldova, Romania and Serbia.
Scutelniciuc, Otilia +5 more
core +1 more source
Survival of Hepatitis C Virus in Syringes Is Dependent on the Design of the Syringe-Needle and Dead Space Volume. [PDF]
Many people who inject drugs (PWID) use syringes with detachable needles, which have high dead space (HDS). Contaminated HDS blood may substantially contribute to the transmission of HIV, hepatitis C (HCV), and other blood-borne viruses within this ...
Mawuena Binka +4 more
doaj +1 more source
VEINROM: A possible solution for erroneous intravenous drug administration
Erroneous intravenous drug administration has a high probability of causing substantial financial consequences along with patient morbidity or mortality. Anesthesiologists and hospital administrators need to be cognizant of the problem.
Anurag Tewari +4 more
doaj +1 more source
Quality inspection and result analysis of the spirometer calibration cylinder
Background To understand the accuracy of volume calibration syringes used in China and compare the difference between new and old volume calibration syringes, technical testing was performed on volume calibration syringes in clinical lung function ...
Zhongping Wu +5 more
doaj +1 more source