Investigation of a thermoluminescent dosimeter mixture between LiF:Mg,Ti and Li2B4O7 in a solid form

open access: yes, 1996
Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the ...
Walkowicz, Joshua Peter
core  

Placement of radiation monitors.

open access: yes, 2014
The operating and assisting surgeon and radiological technologist wore thermoluminescent dosimeter (TLD) badges at the thyroid, chest, genitals (unshielded; circles in A), and on the chest (shielded; dotted circles in A).
Kota Watanabe (453664)   +8 more
core   +1 more source

Dosimetric properties of lif:mg,ti (tld-100) thermoluminescent dosimeter and XR-QA2 radiochromic film dosimeter.

open access: yes, 2012
TEZ9767Tez (Yüksek Lisans) -- Çukurova Üniversitesi, Adana, 2012.Kaynakça (s. 109-118) var.xv, 119 s. : res. (bzs. rnk.), tablo ; 29 cm.Bu çalışmada tıpta kullanılan dozimetrelerden LiF:Mg,Ti (TLD-100) termolüminesans dozimetre ve XR-QA2 model ...
Gürlek, Ali Kazim
core   +1 more source

Investigations of the energy dependence and the response of the dosimeter Panasonic UD802AT in different exposure and energy scenarios

open access: yes, 2013
Mittels Dosimeter, welche für beruflich strahlenexponierte Personen vorgeschrieben sind, kann überprüft werden, ob die vorgeschriebenen Grenzwerte der äußeren Exposition aufgrund des Umganges mit Strahlenquellen eingehalten werden. Ziel der Arbeit ist es
Siquans, Herbert
core   +1 more source

LiB3O5 pyroceramic for thermoluminescent dosimeters [PDF]

open access: yesUkrainian Journal of Physical Optics, 2019
V Adamiv   +5 more
openaire   +1 more source

Simulation of penetration and perforation with CTH

open access: yes, 1993
This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facilities throughout the country for the third ...
Silling, S. A.
core  

Comparative study of radiation dose measurement around 1921r source with manual calculation [PDF]

open access: yes, 2004
The purpose this study is to measure dose around an HDR 1921r source in a vaginal-applicator. The dosimeters used were gafchromic film, and LiF Thermoluminescent dosimeter (TLD 100 chip).
Abdullah, Nazifah
core  

Development of a two-detector thermoluminescent dosimeter reader and its applications

open access: yes, 1995
Vita.A two-detector thermoluminescent dosimeter (TLD) reader was developed which records two different wavelengths of light. The detector has the capability to record two glow curves of different wavelength simultaneously.
Riland, Carson Allen
core   +1 more source

Rethinking dosimeter assignment for military radiation safety

open access: yes선진국방연구
The increasing use of portable X-ray generators in military operations—particularly for explosive detection and counter-terrorism—has highlighted the need for a radiation safety strategy tailored to field-based, low-dose environments.
Hosub Chi   +3 more
doaj  

Can we finally shed the "lead"? Initial Polish experience with the RAMPART Defender radiation shielding system. [PDF]

open access: yesPostepy Kardiol Interwencyjnej
Bujak M   +5 more
europepmc   +1 more source