Thermoluminescent Characteristics of GR-200, TLD-700H and TLD-100 for Low Dose Measurement: Linearity, Repeatability, Dose Rate and Photon Energy Dependence [PDF]
Background: The dose values obtained from procedures of diagnostic radiology are relatively low. To accurately and precisely measure the dose values in this dose range, it is necessary to know the characteristics of dosimeters.Objective: The aim of this ...
Mojgan Alizadeh +5 more
doaj +1 more source
Investigation of Thermal Quenching Effect for Lithium Fluoride (LiF) Type Dosimeters
Thermal quenching is described as a decrease in luminescence efficiency with increasing measurement temperature. Luminescence intensity decreases with increasing heating rates in the presence of thermal quenching.
Engin Aşlar
doaj +1 more source
A method to modify the response of neutron dosimeters in the fields with energy spectra different from the calibration field [PDF]
One problem in neutron dosimetry is that dosimeter responses per unit dose-equivalent in measurement and calibration fields are different. Hence, the neutron dose suffers a large uncertainty.
Amir Moslehi +2 more
doaj +1 more source
Development of a Water Supplement System for a Tuned Liquid Damper under Excitation
Integrating existing liquid storage and supply tanks in buildings with tuned liquid dampers (TLDs) are significant for reducing the effective cost of TLDs.
Congzhen Xiao +4 more
doaj +1 more source
Gamma-heating and gamma flux measurements in the JSI TRIGA reactor, results and prospects [PDF]
The neutron field of various irradiation positions of the TRIGA Mark II reactor of the Jožef Stefan Institute has been thoroughly characterized by neutron activation dosimetry and miniature fission chambers techniques.
Gruel A. +5 more
doaj +1 more source
Study on the coefficient of variation in indian personnel monitoring system [PDF]
The primary parameters for testing an individual monitoring system are standard deviation and the coefficient of variation. The International Electrotechnical Commission (IEC) standard 62387-1 recommends testing the coefficient of variation of ...
Chandrasekhar Sneha +4 more
doaj +1 more source
To ensure optimal prescribing practices in the dolutegravir-era in Cameroon, we compared first-line virological response (VR) under tenofovir + lamivudine + dolutegravir (TLD) according to prior exposure to tenofovir + lamivudine + efavirenz (TLE).
Ezechiel Ngoufack Jagni Semengue +28 more
doaj +1 more source
Characterization of the gamma flux in a tangential channel of the CENM TRIGA MARK II research reactor [PDF]
The CNESTEN (National Center for Energy Sciences and Nuclear Technology, Morocco) operates a TRIGA Mark II reactor, which can reach a thermal maximum power at steady state of 2 MW.
Gruel A. +6 more
doaj +1 more source
The effects of heating rate on the dose response characteristics of TLD-200, TLD-300 and TLD-400
Abstract In the given study; the effects of heating rates on the dose response characteristics of CaF 2 :Dy (TLD-200), CaF 2 :Tm (TLD-300) and CaF 2 :Mn (TLD-400) crystals have been investigated using the dose dependence curve and dose response function f ( D ). It was observed from the dose response functions that the linearity and behaviour of the
Kafadar, V. Emir +2 more
openaire +3 more sources
JSI TRIGA neutron and gamma field characterization by TLD measurements [PDF]
A well characterized radiation field inside a research nuclear reactor irradiation facilities enables precise qualification of radiation effects to the irradiated samples such as nuclear heating or changes in their electrical or material properties.
Ambrožič Klemen +3 more
doaj +1 more source