Results 11 to 20 of about 8,398 (168)

Object Tracking Algorithm with Sparse Prototype Based on TLD [PDF]

open access: yesJisuanji gongcheng, 2017
Tracking-learning-detecting(TLD) object tracking algorithm can achieve a long time online tracking.But when the appearance changes of the object by the plane rotation and the object is occluded,the TLD tracking algorithm tracks drift in the process of ...
ZHOU Junna,CHEN Wei,WANG Ke,CAI Changzheng
core   +2 more sources

Kinerja Tenaga Lapangan Dikmas (TLD) di Provinsi Daerah Istimewa Yogyakarta

open access: yesJurnal Penelitian dan Evaluasi Pendidikan, 2004
Penelitian ini bertujuan untuk mengungkapkan tingkat kinerja tenaga lapangan dikmas (TLD) dan hubungan antara tingkat motivasi berprestasi, tingkat kemampuan dan tingkat iklim organisasi dengan kinerja TED di Provinsi Daerah Istimewa Yogyakarta ...
Kamtijo Kamtijo
core   +3 more sources

Eksternal Radyoterapide Işın Denetimi İçin Yeni Bir TLD Tutucu

open access: yesSüleyman Demirel Üniversitesi Fen-Edebiyat Fakültesi Fen Dergisi, 2013
Bu çalışma da radyoterapi doz kontrolü amacıyla yapılan TLD ışınlamalarında kullanılmak üzere özel bir TLD tutucu dizayn edilmiş ve elde edilen sonuçlar IAEA (International Atomic Energy Agency) tarafından tavsiye edilen yöntem olan plastik kova ...
Bayram Demir   +4 more
core   +1 more source

Perbandingan Tangkapan Dosis Radiasi OSLD NanoDots, TLD-100, dan TLD-100H pada Pemeriksaan Foto Thorax Pasien Anak [PDF]

open access: yes, 2021
Telah dilakukan penelitian tentang perbandingan tangkapan dosis radiasi yang diterima oleh pasien thorax anak menggunakan OSLD nanoDots, TLD-100, dan TLD-100H.
Sofyan, Hasnel   +5 more
core   +4 more sources

Thermoluminescent Characteristics of GR-200, TLD-700H and TLD-100 for Low Dose Measurement: Linearity, Repeatability, Dose Rate and Photon Energy Dependence [PDF]

open access: yesJournal of Biomedical Physics and Engineering, 2022
Background: The dose values obtained from procedures of diagnostic radiology are relatively low. To accurately and precisely measure the dose values in this dose range, it is necessary to know the characteristics of dosimeters.Objective: The aim of this ...
Mojgan Alizadeh   +5 more
doaj   +1 more source

Gamma-heating and gamma flux measurements in the JSI TRIGA reactor, results and prospects [PDF]

open access: yesEPJ Web of Conferences, 2020
The neutron field of various irradiation positions of the TRIGA Mark II reactor of the Jožef Stefan Institute has been thoroughly characterized by neutron activation dosimetry and miniature fission chambers techniques.
Gruel A.   +5 more
doaj   +1 more source

Development of a Water Supplement System for a Tuned Liquid Damper under Excitation

open access: yesBuildings, 2023
Integrating existing liquid storage and supply tanks in buildings with tuned liquid dampers (TLDs) are significant for reducing the effective cost of TLDs.
Congzhen Xiao   +4 more
doaj   +1 more source

Study on the coefficient of variation in indian personnel monitoring system [PDF]

open access: yesNuclear Technology and Radiation Protection, 2016
The primary parameters for testing an individual monitoring system are standard deviation and the coefficient of variation. The International Electrotechnical Commission (IEC) standard 62387-1 recommends testing the coefficient of variation of ...
Chandrasekhar Sneha   +4 more
doaj   +1 more source

Investigation of Thermal Quenching Effect for Lithium Fluoride (LiF) Type Dosimeters

open access: yesCumhuriyet Science Journal, 2023
Thermal quenching is described as a decrease in luminescence efficiency with increasing measurement temperature. Luminescence intensity decreases with increasing heating rates in the presence of thermal quenching.
Engin Aşlar
doaj   +1 more source

A method to modify the response of neutron dosimeters in the fields with energy spectra different from the calibration field [PDF]

open access: yesJournal of Nuclear Research and Applications, 2021
One problem in neutron dosimetry is that dosimeter responses per unit dose-equivalent in measurement and calibration fields are different. Hence, the neutron dose suffers a large uncertainty.
Amir Moslehi   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy