Considerations in the application of the electronic dosimeter to dose of record [PDF]
This report describes considerations for application of the electronic dosimeter (ED) as a measurement device for the dose of record (primary dosimetry).
Swinth, K. L.
core +1 more source
A combined TLD/emulsion method of sampling dosimetry applied to Apollo missions [PDF]
A system which simplifies the complex monitoring methods used to measure the astronaut's radiation exposure in space is proposed. The excess dose equivalents of trapped protons and secondary neutrons, protons, and alpha particles from local nuclear ...
Schaefer, H. J.
core
Simultaneous Double Dose Measurements Using TLD-100H
Thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics applications.
Giuseppe Stella +4 more
doaj +1 more source
Investigation of TLD-700 energy response to low energy x-ray encountered in diagnostic radiology
The aim of thiswork is to study the energy dependence of thermoluminescent dosimeter (TLD-700) for low energy X-ray beams encountered in conventional diagnostic radiology. In the first step, we studied some characteristics (reproducibility and linearity)
Herrati Ammar +2 more
doaj +1 more source
The response of a thermoluminescent dosimeter to low energy protons in the range 30-100 keV
[[abstract]]©2001 Elsevier - This study demonstrates the thermoluminescence (TL) response of CaF2:Tm (commercial name TLD-300) to 30-100 keV protons which were generated by means of a Cockcroft-Walton accelerator.
Chu TC;Lin SY;Hsu CC;Lin JP
core
Site-specific calibration of the Hanford personnel neutron dosimeter [PDF]
A new personnel dosimetry system, employing a standard Hanford thermoluminescent dosimeter (TLD) and a combination dosimeter with both CR-39 nuclear track and TLD-albedo elements, is being implemented at Hanford.
Rathbone, B. A. +3 more
core
Thermoluminescent dosimeter (TLD) has been used for postal dose audit by IAEA, ESTRO and RPC. TLD is small enough to handle easily and have fine accuracy up to these days.
Mizuno, Hideyuki +21 more
core
The environmental radiation dose depends on many factors, which have to be taken into account when monitoring programs are implemented. The aim of this study was to analyze the fading, reproducibility, and sensitivity changes over time in LiF:Mg,Cu,P ...
Pablo Andres
doaj +1 more source
Background: The present study is aimed at calculating relative absorbed-dose energy response correction (R) of commonly used thermoluminescent dosimeters (TLDs) such as LiF, Li2B4O7, and Al2O3 as a function of depth in water for protons (50–250 MeV/n ...
Arghya Chattaraj +2 more
doaj +1 more source
Thermoluminescent Detectors in Mixed Fields
This note reports on using of thermoluminescent detectors for radiation monitoring in the LHC tunnel and in the shielded areas around the tunnel. The accumulated annual doses in these areas vary a lot so a dosimeter used there should cover a large dose ...
Biskup, B, Mala, P, Roeed, K, Brugger, M
core