Thermoluminescent dosimeter (CaF/sub 2/:Dy) measurement of the Hanford environs, 1971--1975
The average external dose rate measured at locations in the Hanford environs was 72 mrad/year, based on analysis of thermoluminescent dosimeter data collected from 1971 through 1975.
Blumer, P. J. +3 more
core +1 more source
Pulse‐to‐pulse analysis of ultra‐high dose per pulse electron beams using beam current transformers
Abstract Background Ultra‐high dose per pulse (UHDPP) beams have shown to be promising for clinical applications due to their healthy tissue sparing potential. In this radiotherapy modality, a limited number of pulses (often < 25) can deliver the prescribed dose, making pulse‐to‐pulse beam stability essential for accurate dose delivery. In this context,
Miguel A Flores‐Mancera +2 more
wiley +1 more source
Abstract Background Small‐field dosimetry plays a pivotal role in stereotactic body radiation therapy (SBRT), where high‐precision dose delivery is essential. In multi‐institutional clinical trials, quality assurance (QA) becomes increasingly critical due to the variability in linear accelerator (linac) output calibration and treatment planning system (
Daisuke Kawahara +15 more
wiley +1 more source
Objective: This study aimed to evaluate the current state of radiation protection knowledge and practices of interventional cardiologists (ICs), including fellow doctors, in Saudi Arabia during cardiac catheterization procedures.
Areej Alharbi +7 more
doaj +1 more source
Applicability of topaz composites to electron dosimetry [PDF]
Thermoluminescent dosimetric topaz properties have been investigated and the results have shown that this mineral presents characteristics of a good dosimeter mainly in doses evaluation in radiotherapy with photons beams in radiotherapy.
Souza, Divanizia do Nascimento +1 more
core +1 more source
Thermoluminescent neutron dosimeter with internal energy: response correction
Personnel exposures at Mound are to unmoderated and moderated neutrons from (..cap alpha..,n) reactions and to spontaneous fission and neutron induced fissions from /sup 238/Pu and /sup 252/Cf (an enriched-uranium subcritical assembly).
Anderson, M.E., Crain, S.L.
core
Desenvolvimento de um dosímetro in vivo a MOSFET para aplicações em radioterapia [PDF]
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2013.Na radioterapia (teleterapia), a diferença entre a dose prescrita e a dose recebida pelo paciente deve ...
Siebel, Osmar Franca
core
Assessment and optimization of scattered radiation in computed tomography: A review of measurement techniques, dosimetry tools, and radiation protection strategies [PDF]
Background: Off-target patient doses and occupational personnel exposure are caused by Computed Tomography (CT) induced dispersed radiation. Even with improvements in CT equipment and dosage reduction techniques, routine scatter field measurement and ...
Bisma Amin +4 more
doaj
A comparison of skin dose estimation between thermoluminescent dosimeter and treatment planning system in prostatic cancer: A brachytherapy technique. [PDF]
Majdaeen M +6 more
europepmc +1 more source
Research on DIS Dosimeter Based on TCAD Simulation Method
Personal dose monitoring and environmental radiation monitoring are commonly conducted in places such as nuclear power plant reactor operations and nuclear medical facilities,often using thermoluminescent dosimeters (TLD).
Jiaqi XU +5 more
doaj +1 more source

