Results 51 to 60 of about 16,963 (213)

Thermoluminescence Properties of Aluminium Oxide doped Strontium, Lithium and Germanium prepared by Combustion Synthesis method

open access: yesEPJ Web of Conferences, 2017
In this work, Al2O3 doped with Sr, Li and Ge was prepared by combustion synthesis techniques for thermoluminescent (TL) ionizing radiation dosimetry applications.
Binti Saharin Nurnl Syazlin   +3 more
doaj   +1 more source

Organ Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms [PDF]

open access: yesIranian Journal of Medical Physics, 2019
Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use.
Michael Akpochafor   +9 more
doaj   +1 more source

Comparative Evaluation of Four Stereotactic Radiosurgery Planning Approaches for Treatment of Posterior Choroidal Melanoma

open access: yesJournal of Medical Radiation Sciences, Volume 73, Issue 3, Page 250-258, September 2026.
This study evaluated four stereotactic radiosurgery planning approaches for posterior choroidal melanoma (CM). Analysis of thirteen CM cases resulted in a clinically meaningful reduction in dose to the brain for Brainlab Elements modulated arcs (BE) and Varian Eclipse HyperArc modulated arcs (HA) compared to Brainlab iPlan dynamic conformal arc therapy
Robert Nigro   +5 more
wiley   +1 more source

Response of the Hanford Combination Neutron Dosimeter in plutonium environments [PDF]

open access: yes, 1996
This report documents response characteristics and the development of dose algorithms for the Hanford Combination Neutron Dosimeter (HCNO) implemented on January 1, 1995. The HCND was accredited under the U.S.
Brackenbush, L.W.   +2 more
core   +1 more source

Transporter‐Associated Therapeutic Efficacy of an SMVT‐Targeted Boron Carrier in Boron Neutron Capture Therapy

open access: yesCancer Science, Volume 117, Issue 9, Page 2555-2566, September 2026.
The transporter‐associated BNCT strategy using BBCIP with or without BPA according to tumor transporter characteristics. BPA showed greater efficacy in LAT1‐dominant F98 glioma, whereas BBCIP was more effective in SMVT‐high CRL1666 tumors, suggesting the potential utility of transporter‐based boron carrier selection in BNCT.
Kenichiro Eza   +15 more
wiley   +1 more source

Development of a Polydimethylsiloxane‐Based Flexible Digital Bolus Dosimeter: From Unit‐Cell Characterization to Linear Array for Skin‐Dose Distribution Verification

open access: yesphysica status solidi (a), Volume 223, Issue 15, 5 August 2026.
A flexible digital bolus dosimeter platform is proposed to address the challenges of surface‐dose monitoring. The study evaluates point‐dose performance using an IDE substrate and extends this to spatial dose distributions using an fPCB‐integrated 24‐pixel array.
Moo‐Jae Han   +7 more
wiley   +1 more source

A Comparison of Readings from Thermoluminescent Dosimeter Ring Badges Worn in Different Positions [PDF]

open access: yes, 2020
Our purpose was to evaluate whether the position of a thermoluminescent dosimeter (TLD) crystal results in different exposure readings. Methods: Nine subjects wore 2 TLD badges (one facing inward, toward the palm, and one facing outward) for 2 mo.
Osborne, Keexia L.   +7 more
core   +1 more source

Assessment of dose distribution in pancreatic SABR in the presence of a metallic biliary stent using Monte Carlo modeling

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Stereotactic ablative radiotherapy (SABR) with dose escalation is increasingly used for pancreatic cancer; however, the dosimetric impact of metallic biliary stents remains poorly characterized. Self‐expanding metal stents (SEMS), commonly placed for obstructive jaundice, contain high‐density nitinol that produces computed ...
Ahmad Abbas   +2 more
wiley   +1 more source

Studies of the Al2O3:C thermoluminescent dosimeter

open access: yes, 1995
Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the ...
Naquin, Tyrone Daniel
core   +1 more source

Systematic review of physical and dosimetric criteria for managing CIEDs in radiotherapy: A medical physicist's perspective

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Aim Current radiotherapy (RT) guidelines for Cardiac Implantable Electronic Devices (CIEDs) are largely based on clinical management strategies and retrospective reports. This systematic review adopts a medical physics perspective to provide a critical, quantitative analysis of the technical evidence required for developing robust safety ...
Tiziana Malatesta   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy