Results 51 to 60 of about 16,963 (213)
In this work, Al2O3 doped with Sr, Li and Ge was prepared by combustion synthesis techniques for thermoluminescent (TL) ionizing radiation dosimetry applications.
Binti Saharin Nurnl Syazlin +3 more
doaj +1 more source
Organ Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms [PDF]
Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use.
Michael Akpochafor +9 more
doaj +1 more source
This study evaluated four stereotactic radiosurgery planning approaches for posterior choroidal melanoma (CM). Analysis of thirteen CM cases resulted in a clinically meaningful reduction in dose to the brain for Brainlab Elements modulated arcs (BE) and Varian Eclipse HyperArc modulated arcs (HA) compared to Brainlab iPlan dynamic conformal arc therapy
Robert Nigro +5 more
wiley +1 more source
Response of the Hanford Combination Neutron Dosimeter in plutonium environments [PDF]
This report documents response characteristics and the development of dose algorithms for the Hanford Combination Neutron Dosimeter (HCNO) implemented on January 1, 1995. The HCND was accredited under the U.S.
Brackenbush, L.W. +2 more
core +1 more source
The transporter‐associated BNCT strategy using BBCIP with or without BPA according to tumor transporter characteristics. BPA showed greater efficacy in LAT1‐dominant F98 glioma, whereas BBCIP was more effective in SMVT‐high CRL1666 tumors, suggesting the potential utility of transporter‐based boron carrier selection in BNCT.
Kenichiro Eza +15 more
wiley +1 more source
A flexible digital bolus dosimeter platform is proposed to address the challenges of surface‐dose monitoring. The study evaluates point‐dose performance using an IDE substrate and extends this to spatial dose distributions using an fPCB‐integrated 24‐pixel array.
Moo‐Jae Han +7 more
wiley +1 more source
A Comparison of Readings from Thermoluminescent Dosimeter Ring Badges Worn in Different Positions [PDF]
Our purpose was to evaluate whether the position of a thermoluminescent dosimeter (TLD) crystal results in different exposure readings. Methods: Nine subjects wore 2 TLD badges (one facing inward, toward the palm, and one facing outward) for 2 mo.
Osborne, Keexia L. +7 more
core +1 more source
Abstract Background Stereotactic ablative radiotherapy (SABR) with dose escalation is increasingly used for pancreatic cancer; however, the dosimetric impact of metallic biliary stents remains poorly characterized. Self‐expanding metal stents (SEMS), commonly placed for obstructive jaundice, contain high‐density nitinol that produces computed ...
Ahmad Abbas +2 more
wiley +1 more source
Studies of the Al2O3:C thermoluminescent dosimeter
Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the ...
Naquin, Tyrone Daniel
core +1 more source
Abstract Aim Current radiotherapy (RT) guidelines for Cardiac Implantable Electronic Devices (CIEDs) are largely based on clinical management strategies and retrospective reports. This systematic review adopts a medical physics perspective to provide a critical, quantitative analysis of the technical evidence required for developing robust safety ...
Tiziana Malatesta +15 more
wiley +1 more source