Results 101 to 110 of about 20,532,860 (296)
Comparison between flexural wood strength values obtained from three-point and four-point bending tests in wood were only reported in few previous works, but remains unclear.
Ricardo Gherardi HEIN, Loïc BRANCHERIAU
doaj
From Food to Power: Hydrogel Thermoelectrics for Ingestible Electronics
We introduce a fully edible thermoelectric–electrochromic platform that harvests heat from food and converts it into a visible color change. N‐type and p‐type hydrogel thermoelectric generators connected in series power anthocyanin‐based electrochromic displays, demonstrating the feasibility of safe, biodegradable, ingestible systems for on‐food ...
Antonia Georgopoulou +3 more
wiley +1 more source
ABSTRACT Chitosan, a polysaccharide upcycled from biowaste, has long promised sustainable, biocompatible, and antimicrobial films and devices, an appeal reinforced by its recent regulatory recognition, with several chitosan‐based antibacterial dressings gaining clearance through the Food and Drug Administration's 510(k) pathway.
Jacopo Nicoletti +16 more
wiley +1 more source
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
Comparison of stress of both sclerites obtained from three-point bending test.
Comparison of stress of both sclerites obtained from three-point bending test.
Takuro Noguchi (178782) +20 more
core +1 more source
Experimental test on 3D-printing components for Architectural Restoration
The paper investigates the use of 3D-printed components made from Polylactic Acid (PLA) for the restoration of architectural and ornamental elements, focusing on architectural/structural components.
Valentina Tomei +2 more
doaj +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
Numerical modelling of Three - Point Bending Test
U radu je provedena numerička analiza naprezanja i deformacija u linearno elastičnom i nelinearno plastičnom području na epruvetama za vlačno ispitivanje i na epruvetama bez zareza za savijanje u tri točke.
Frančeski, Joško
core
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source

