Results 41 to 50 of about 19,317 (224)

Ferromagnetically Shielded Fault Current Limiter (FS‐FCL) Evaluation in Power Line

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This study introduces a new ferromagnetically shielded FS‐FCL design and its control strategy for limiting and interrupting fault currents. The fully shielded core structure enhances inductance and prevents saturation, enabling an immediate fault response without causing voltage drop during normal conditions.
Kamran Ghorbanyan, Selim Acar
wiley   +1 more source

Multi‐Layer MTDC Protection: Design and Simulation Assessment

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This study proposes a novel multi‐layer protection architecture for multi‐terminal DC systems that separates fault current‐limiting and interruption functions. By combining a thyristor‐based fault current limiter with an active resonance circuit breaker, the scheme significantly reduces peak fault currents and di/dt stress, enabling a more compact ...
Jong‐Geon Lee   +3 more
wiley   +1 more source

Research on Equivalent Circuit Model of HVDC Valve and Calculation of Thyristor Junction Temperature

open access: yesActive and Passive Electronic Components
For the difference of thyristor junction temperature at all levels in the transducer valve assembly in the series water circuit, an equivalent model of thyristor junction temperature calculation for the valve assembly is established, and PLECS simulation
Wei Yao   +5 more
doaj   +1 more source

Real-Time Monitoring Method for Thyristor Losses in Ultra High Voltage Converter Station Based on Wavelet Optimized GA-BP Neural Network

open access: yesIEEE Access, 2023
As the core equipment for AC/DC conversion in ultra-high voltage direct current (UHVDC) transmission systems, thyristor converter valves are the main source of losses in converter stations.
Jicheng Yu   +7 more
doaj   +1 more source

Non‐Contact Turn‐Off Time Measurement Method for IGBTs in the Half‐Bridge Submodule Configuration of MMC

open access: yesIET Power Electronics, Volume 19, Issue 1, January/December 2026.
This paper proposes a non‐contact method for measuring the turn‐off time of insulated‐gate bipolar transistor (IGBT) devices in modular multilevel converters (MMC) submodules, using the decay of load‐side common‐mode current. The technique leverages existing current‐sensing infrastructure and avoids intrusive modifications, enabling real‐time ...
Jiyun Liu   +7 more
wiley   +1 more source

A Parameter Design Method for SVC Considering the Impedance Interaction Between Inverters and Reactive Compensation Devices

open access: yesIET Power Electronics, Volume 19, Issue 1, January/December 2026.
Distributed generation (DG) aggregation points are typically equipped with reactive compensation devices to maintain voltage stability. However, improper parameter design may cause harmonic oscillations due to interactions between the device and inverter impedance.
Chengjia Bao   +4 more
wiley   +1 more source

Diagnostics of the thyristor bridge fault based on the detection of the line-frequency second harmonic in the output current of an AC/DC converter [PDF]

open access: yesTehnika, 2018
In this paper was presented the technical procedure implemented for the fault diagnostics of the thyristor bridge in an AS/DC converter. During the development of the new generation of digital controllers for AC/DC converters, it was required for these ...
Vukić Vladimir Đ., Prole Rajko Đ.
doaj  

Three‐Level NF‐TDN Controller for AGC in Thermal‐Hydro‐Gas Power Systems Integrated With TCPS Under Nonlinear Conditions

open access: yesInternational Journal of Energy Research, Volume 2026, Issue 1, 2026.
Automatic generation control (AGC) is vital for preserving frequency and power balance in modern interconnected power systems (IPSs), which are increasingly challenged by nonlinear dynamics, parameter uncertainties, and unpredictable load variations.
Getaneh Mesfin Meseret, Mohammad Ghiasi
wiley   +1 more source

Wide‐area damping control in renewable integrated power systems: A review on recent achievements and new challenges

open access: yesEnergy Conversion and Economics, Volume 6, Issue 6, Page 341-358, December 2025.
Abstract Low‐frequency oscillations (LFOs) remain a major obstacle to maintaining stable dynamic performance in power systems with high levels of renewable energy integration. In particular, inter‐area LFOs have emerged as a critical concern in large, interconnected grids.
Linglin Meng   +10 more
wiley   +1 more source

Fast-Read Storage Performance by Thyristor Operation in 3-D Flash Memory

open access: yesIEEE Journal of the Electron Devices Society
In this work, we report the fast-read storage performance of thyristor operation in 3D flash memory. By forming a pseudo N+/P/N/P+ structure with the word line (WL) bias of 3D string cells, thyristor operation with steep switching characteristics and a ...
Tomoya Sanuki   +2 more
doaj   +1 more source