Results 21 to 30 of about 19,817 (226)
High Harmonic Reduction Using Passive Filters of Mountain Steel Company
An increasing amount of power electronics has created an immediate effect on the value of the electrical power source. Both of high control manufacturing loads and national loads explain harmonic in the system voltage.
Asmahan Y. Husen +2 more
doaj +1 more source
This article describes an enhanced switched capacitor cross‐connected switched multilevel inverter (ESC3SMLI) with machine learning‐based model‐predictive control (ML‐MPCM). An improved switched capacitor cross connected switched multilevel inverter featuring minimal devices are presented. The proposed ESC3SMLI produces nine levels using eight switches,
Arun Vijayakumar +4 more
wiley +1 more source
Real‐time estimating harmonic distortion levels near the Point of Interconnections of grid‐connected inverter‐based resources (IBRs) is critical for maintaining the operational reliability and security of the power grid, particularly during transients ...
Reza Saeed Kandezy +3 more
doaj +1 more source
Suppression of line voltage related distortion in current controlled grid connected inverters [PDF]
The influence of selected control strategies on the level of low-order current harmonic distortion generated by an inverter connected to a distorted grid is investigated through a combination of theoretical and experimental studies.
Abeyasekera, T. +3 more
core +2 more sources
An innovative switched‐capacitor‐based inverter is proposed in this article. The suggested converter can produce a five‐level output voltage by utilizing minimal components (single dc source, six switches, and one capacitor). The effectiveness of the suggested inverter is verified by experimental results using hardware in loop OPAL‐RT OP4510.
Tamiru Debela +2 more
wiley +1 more source
Interpretation of partial discharge activity in the presence of harmonics [PDF]
Recent work has identified that circumstances of equipment operation can radically change condition monitoring data. This contribution investigates the significance of considering circumstance monitoring on the diagnostic interpretation of such condition
Bahadoorsingh, S. +4 more
core +1 more source
This paper proposes a new Double T‐type H‐bridge (DTH) module configuration that can produce 9, 13, 17, 19, 21, and 25 levels using reduced components. Abstract Renewable energy sources are subject to input source uncertainties, which can negatively impact output voltage THD.
Omid Zolfagharian +2 more
wiley +1 more source
Application of Genetic Algorithm to Minimize Harmonic in Multilevel Inverter
In inverter design, harmonic voltage is the main issue which affects the performance of the inverter. Generally, the harmonic minimization problem complexity is influenced by the number of harmonic orders to be minimized.
Firmansyah Nur Budiman +2 more
doaj +3 more sources
Penguat Audio Kelas D Dengan Umpan Balik Tipe Butterworth
A class D amplifier would, in ideal sense, amplify signals without any noises and distortions which yield 100% efficiency and 0% Total Harmonic Distortion (THD).
Gunawan Dewantoro +2 more
doaj +1 more source
This article presents a Fifteen‐level inverter topology that has a lesser number of switches (12) and can accommodate isolated DC sources. The total harmonic elimination (THD) of the proposed topology using genetic algorithm is within the IEEE 519 standards. Further, the fifteen‐level inverter is implemented in Hardware and firing pulses were generated
Yogesh Joshi +4 more
wiley +1 more source