Results 81 to 90 of about 13,209 (233)
Substations are a vital part of the electric power system and therefore require properly designed grounding systems to ensure protection of persons working in the vicinity of earthed facilities from danger of electric shock, safeguard of equipment ...
Hachimenum Amadi (727629)
core +1 more source
Hierarchical multi‐material TPMS lattices are engineered as flexible tactile sensors by combining soft and stiff elastomeric layers with a conformal conductive coating. The bilayer architecture delivers sensitivity at low pressures while maintaining a broad detectable range under large loads, enabling reliable pressure and vibration monitoring for ...
Reza Noroozi +3 more
wiley +1 more source
Design of a Substation Grounding System for Fast Front Overvoltage
Grounding studies allow an optimized design of grounding system to provide protection for electrical components and personnel at substation. The design of grounding system needs to comply with IEEE Standard 80:2013.
Lee, Kevin Yuan Jet +2 more
core +1 more source
A flexible piezoresistive pressure sensor with gradient toroidal CNT/PDMS microstructures is reported. The hierarchical geometry enables sequential electrode contact, achieving a sensitivity of 256.20 kPa−1 and linear response (R2 = 0.99) over 0–1000 kPa.
Rongmei Wang +8 more
wiley +1 more source
Analysis of the grounding system of a high voltage substation
U diplomskom radu teorijski su obrađeni pojmovi otpora rasprostiranja, napona koraka, dodirnog napona i uzemljenja nadalje, dane su osnovne podjele uzemljivača i sustava uzemljenja. Objašnjeni su utjecaji struje na ljudsko tijelo i sigurnost tokom rada u
Kuric, Dominik
core
3D‐Printed Dual‐Doped Ag2Se‐Based Thermoelectric Films With Enhanced Thermal Stability
Sb–Se dual doping enhances the thermal stability of Ag2Se‐based thermoelectric systems. The compositionally tuned nano‐ink is printed into flexible films by direct ink writing (DIW), retaining improved thermoelectric properties after annealing up to 400°C.
Ahasun Habib Hridoy +8 more
wiley +1 more source
Study of step voltage and touch voltage in a photovoltaic installation, due to lightning strikes
Στην παρούσα διπλωματική εργασία αναλύονται τα μεταβατικά φαινόμενα που προκαλούνται εξ' αιτίας ενός κεραυνικού πλήγματος σε μια φωτοβολταϊκή εγκατάσταση, και πιο συγκεκριμένα η βηματική τάση και η τάση επαφής στον άνθρωπο.
Καραγιάννης, Βασίλειος
core
The distribution of fault current in the grounding system of high voltage electrical power plants [PDF]
Ovaj rad daje opis raspodjela struja kvara unutar uzemljivačkog sustava visokonaponskog elektroenergetskog postrojenja. Nakon uvoda, u drugom poglavlju, slijedi definiranje dodirnog napona te napona koraka, govori se i o raspodjeli potencijala.
Sukser, Franjo
core +1 more source
Dense tactile streams from across the humanoid body converge on collide in a central wiring and data bottleneck. By relocating computation closer to and then into the skin itself, near‐ and in‐sensor architectures, together with neuromorphic computing, chart a path toward perception‐native electronic skin, in which the conversion of stimulus into ...
Mijin Kim +6 more
wiley +1 more source
Analisis Sistem Pentanahan Grid Gardu Induk pada Dua Lapis Tanah
The substation is a terminal that connects the transmission lines and distribution lines. One of the security systems used in substations is using a safe and good grounding system.
Harahap, Iwan Saleh