Results 281 to 290 of about 6,830,142 (327)
Some of the next articles are maybe not open access.

Optical Current Transformer Accuracy Problems and Solutions

2010 Asia-Pacific Conference on Power Electronics and Design, 2010
Explain the factors which affect the performance of optical current transformer (OCT) and Solutions. Signal processing measure is the key to the application of optical current transformer. Therefore the signal processing system’s improved method of optical current transformer was introduced, and prospects the future development of optical current ...
Guo Weina, Huang Wenjie
openaire   +1 more source

Transforming the empirical likelihood towards better accuracy

Canadian Journal of Statistics, 2017
AbstractUnder‐coverage has been a long‐standing issue with the empirical likelihood confidence region. Several methods can be used to address this issue, but they all add complexity to the empirical likelihood inference requiring extra computation and/or extra theoretical investigation.
Bing‐Yi Jing, Min Tsao, Wang Zhou
openaire   +3 more sources

Zoom transform for mass measurement accuracy in Fourier transform mass spectrometry

Analytical Chemistry, 1983
On decrit une methode d'analyse numerique appelee la transformation zoom. Elle est mise en œuvre en appliquant les transformations de Fourier inverse et avant aux donnees de spectrometrie de ...
Thomas J. Francl   +2 more
openaire   +1 more source

Accuracy of Multivariable Refinable Functions and Two-Scale Similarity Transform

Acta Mathematica Sinica, 2000
The paper considers refinable function vectors \(\Phi\) with dilation matrix \(M=\text{diag}(2,2,\dots, 2)\). Let \(m(\xi)\) be a refinement symbol of the refinable vector \(\pmb\Phi\) and let \(\Phi\) provide accuracy \(p\). Then, under some additional conditions, the vector \(\pmb\Psi\) with refinement symbol \[ \tilde m(\xi)=T( 2\xi)^{-1}m(\xi)T(\xi)
Sheng, Qiuhui, Peng, Silong
openaire   +2 more sources

The effect of instrument transformer accuracy class on the WLS state estimator accuracy

2013 IEEE Power & Energy Society General Meeting, 2013
The measurement chain of the power system consists of various components introducing their associated uncertainty to the measured quantity. Although, it is important to identify and quantify the individual uncertainties of the measurement chain components and consequently the combined measurement chain uncertainty, it is nearly impossible to do this ...
Asprou, M.   +5 more
openaire   +2 more sources

High-accuracy formula for discrete calculation of fourier transforms

Applied Mathematics and Computation, 1999
zbMATH Open Web Interface contents unavailable due to conflicting licenses.
openaire   +2 more sources

Abridgment of a new high-accuracy current transformer

Journal of the A.I.E.E., 1929
This paper is presented for the purpose of describing a new method of compensation, by the use of which the ratio and phase-angle errors of current transformers are materially reduced. There are several similar methods now in use, but these methods possess some undesirable features which are not present in the one described in this paper. By the use of
openaire   +1 more source

Accuracy Performance of Power Voltage Transformers

Mediterranean Conference on Power Generation, Transmission, Distribution and Energy Conversion (MEDPOWER 2018), 2018
I. Žiger   +3 more
openaire   +1 more source