Results 41 to 50 of about 125,561 (280)

Perbandingan Pengaruh Penempatan Arrester Sebelum dan Sesudah Fco sebagai Pengaman Transformator 3 Phasa terhadap Gangguan Surja Petir di Penyulang Pandean Lamper 5 Rayon Semarang Timur [PDF]

open access: yes, 2014
Azis Nurrochma Wardana, Arkhan Subari, in paper comparison of the effect of placement arrester before and after FCO as safety of 3 phase transformator from interruption of lightning at Pandean Lamper 5 Feeder, East Semarang explain that problem of the ...
Subari, A. (Arkhan)   +1 more
core  

Exploiting multi-agent system technology within an autonomous regional active network management system [PDF]

open access: yes, 2007
This paper describes the proposed application of multi-agent system (MAS) technology within AuRA-NMS, an autonomous regional network management system currently being developed in the UK through a partnership between several UK universities, distribution
Davidson, Euan M.   +1 more
core   +1 more source

Peptide‐based ligand antagonists block a Vibrio cholerae adhesin

open access: yesFEBS Letters, EarlyView.
The structure of a peptide‐binding domain of the Vibrio cholerae adhesin FrhA was solved by X‐ray crystallography, revealing how the inhibitory peptide AGYTD binds tightly at its Ca2+‐coordinated pocket. Structure‐guided design incorporating D‐amino acids enhanced binding affinity, providing a foundation for developing anti‐adhesion therapeutics ...
Mingyu Wang   +9 more
wiley   +1 more source

DC fault isolation study of bidirectional dual active bridge DC/DC converter for DC transmission grid application [PDF]

open access: yes, 2015
Fast isolation and detection of DC faults is currently a limiting factor in high power DC transmission grid development. Recent research has shown that the role of DC/DC converters is becoming increasingly important in solving various DC grid challenges ...
Aboushady, Ahmed A.   +2 more
core   +2 more sources

Interplay between circadian and other transcription factors—Implications for cycling transcriptome reprogramming

open access: yesFEBS Letters, EarlyView.
This perspective highlights emerging insights into how the circadian transcription factor CLOCK:BMAL1 regulates chromatin architecture, cooperates with other transcription factors, and coordinates enhancer dynamics. We propose an updated framework for how circadian transcription factors operate within dynamic and multifactorial chromatin landscapes ...
Xinyu Y. Nie, Jerome S. Menet
wiley   +1 more source

Transformer Differential Protection Lab [PDF]

open access: yes, 2016
The purpose of the Transformer Differential Protection Lab senior design project is to implement the transformer differential protection scheme to protect a transformer when an internal fault is applied.
Dunbar, Justin   +2 more
core   +1 more source

Analysis of energy dissipation in resistive superconducting fault-current limiters for optimal power system performance [PDF]

open access: yes, 2011
Fault levels in electrical distribution systems are rising due to the increasing presence of distributed generation, and this rising trend is expected to continue in the future.
Blair, Steven Macpherson   +4 more
core   +1 more source

The role of histone modifications in transcription regulation upon DNA damage

open access: yesFEBS Letters, EarlyView.
This review discusses the critical role of histone modifications in regulating gene expression during the DNA damage response (DDR). By modulating chromatin structure and recruiting repair factors, these post‐translational modifications fine‐tune transcriptional programmes to maintain genomic stability.
Angelina Job Kolady, Siyao Wang
wiley   +1 more source

Dynamic Differential Current-based Transformer Protection Using a Convolutional Neural Network

open access: yesCSEE Journal of Power and Energy Systems
A reliable transformer protection method is crucial for power systems. Aiming at improving the generalization performance and response speed of multi-feature fusion based transformer protection, this paper presents a dynamic differential current by ...
Zongbo Li, Zaibin Jiao, Anyang He
doaj   +1 more source

Analisis Kinerja Sistem Proteksi Berdasarkan Frekuensi Gangguan di Gardu Induk 150 KV Garuda Sakti [PDF]

open access: yes, 2017
With the disruption that can not be predicted, we need a safety equipment (protection system) are precise and reliable. The purpose of this study was to determine the quantity of interference, protection system performance, reliability and power ...
\u27, A. (Ardianto)   +2 more
core  