Results 1 to 10 of about 763 (183)
As a predominant issue within line-commutated converters-based high voltage direct current (DC) transmission systems, commutation failure may trigger transient overvoltage problems and the tripping of large-scale renewable generation sets in hybrid AC/DC
Boyu Qin +4 more
doaj +1 more source
Analysis of Overvoltages on Power Transformer Recorded by Transient Overvoltage Monitoring System
In this paper, an on-line transient overvoltage monitoring system (TOMS) for power transformers is used for measurement of overvoltages on the transformer bushing tap. The focus of the paper is on the analysis of transient overvoltages caused by lightning strikes recorded at the terminals of power transformer. Several recorded overvoltages are analyzed
Murat, Ivan +5 more
openaire +3 more sources
In regions with extensive wind power collection, the grid’s robustness diminishes, and transient overvoltage phenomena during the restoration phase following an AC short-circuit fault pose significant challenges to secure and stable operation ...
Xu Tian +5 more
doaj +1 more source
This paper presents an electromagnetic transient analysis of lightning-initiated overvoltage stresses of the step-up transformers installed inside a nacelle of onshore, multi-megawatt, new-generation wind turbines.
Petar Sarajcev, Antun Meglic, Ranko Goic
doaj +1 more source
With the increasing proportion of new energy in power systems, the instability issues of novel power systems become more prominent. This paper addresses the transient overvoltage problem in wind power DC transmission systems by proposing a method for ...
Jie Zhao +6 more
doaj +1 more source
Infeasibility Analysis of Half-Wavelength Transmission Systems
This paper analyzes the infeasibility of half-wavelength transmission systems in the aspects of power-frequency overvoltage and synchronization stability. The circuit model of the long-distance transmission system is established at first for steady-state
Zheng Xu, Jian Yang, Nengjin Sheng
doaj +1 more source
The transient overvoltage at the sending terminal of the offshore wind power collection and transmission system with AC cables threatens the safe and stable operation of the system.
Yanxia SUN, Shiwen FANG, Zhen LI
doaj +1 more source
As the ‘dual carbon’ goals continue to advance in China, the grid‐connected scale of new energy power generation equipment such as wind power and photovoltaic power is constantly increasing.
Shiyun Xu +4 more
doaj +1 more source
The growing reliance on high-power high-voltage direct current (HVDC) transmission systems has intensified challenges associated with transient AC overvoltage induced by commutation failures resulting from converter operation characteristics.
Xiyu Yin +6 more
doaj +1 more source
The multiple reignitions of vacuum circuit braker (VCB) while switching off the shunt reactor in an offshore wind farm (OWF) would produce a high overvoltage. The post‐arc process of ion movement in the vacuum interrupter is analysed.
Zhi Zheng +5 more
doaj +1 more source